Configure SR-IOV agent-config.yaml with Device by Path
Use agent-config.yaml to select network devices by PCI path for SR-IOV VF creation, ensuring deterministic NIC targeting across OpenShift nodes.
💡 Quick Answer: Use
agent-config.yamlwithdevicesByPathto select SR-IOV physical functions by their stable PCI bus address instead of interface name, ensuring consistent VF creation even when interface names change across reboots or OS upgrades.
The Problem
When deploying SR-IOV on bare-metal OpenShift nodes, interface names like ens3f0 or enp65s0f0 can change between reboots, BIOS updates, or OS upgrades. If your SriovNetworkNodePolicy targets a device by name and that name shifts, VF creation silently fails — or worse, targets the wrong NIC.
You need a stable, hardware-anchored way to identify which physical function (PF) gets SR-IOV VFs.
The Solution
The agent-config.yaml file used during OpenShift installation supports devicesByPath selection, which references the PCI bus address of each NIC. PCI paths are determined by physical slot position and don’t change unless you physically move the card.
Architecture Overview
graph TD
A[agent-config.yaml] -->|devicesByPath| B[PCI Address<br/>0000:65:00.0]
B --> C[Physical Function<br/>PF0]
C --> D[VF0]
C --> E[VF1]
C --> F[VF2...VFn]
A -->|devicesByPath| G[PCI Address<br/>0000:65:00.1]
G --> H[Physical Function<br/>PF1]
H --> I[VF0]
H --> J[VF1]
H --> K[VF2...VFn]
style A fill:#326CE5,color:#fff
style B fill:#f9a825,color:#000
style G fill:#f9a825,color:#000Step 1: Discover PCI Paths on Your Nodes
Before writing the config, identify each NIC’s PCI address:
# List all network devices with PCI addresses
lspci | grep -i ethernetExample output:
65:00.0 Ethernet controller: Mellanox Technologies MT2910 Family [ConnectX-7]
65:00.1 Ethernet controller: Mellanox Technologies MT2910 Family [ConnectX-7]
ca:00.0 Ethernet controller: Mellanox Technologies MT2910 Family [ConnectX-7]
ca:00.1 Ethernet controller: Mellanox Technologies MT2910 Family [ConnectX-7]Map PCI addresses to interface names:
# Show interface-to-PCI mapping
ls -la /sys/class/net/*/device | awk -F'/' '{print $(NF-2), $NF}'Or use a single command per interface:
# Get PCI address for a specific interface
ethtool -i ens3f0 | grep bus-info
# bus-info: 0000:65:00.0Step 2: Write agent-config.yaml with devicesByPath
Use the full PCI path in your agent-config.yaml:
apiVersion: v1alpha1
kind: AgentConfig
metadata:
name: my-cluster
rendezvousIP: 192.168.10.10
hosts:
- hostname: worker-0
role: worker
interfaces:
- name: eno1
macAddress: "aa:bb:cc:dd:ee:01"
- name: ens3f0
macAddress: "aa:bb:cc:dd:ee:10"
- name: ens3f1
macAddress: "aa:bb:cc:dd:ee:11"
networkConfig:
interfaces:
- name: eno1
type: ethernet
state: up
ipv4:
enabled: true
dhcp: true
sr-iov:
devices:
- name: ens3f0
devicesByPath:
- /dev/pci/0000:65:00.0
numVfs: 8
- name: ens3f1
devicesByPath:
- /dev/pci/0000:65:00.1
numVfs: 8
- hostname: worker-1
role: worker
interfaces:
- name: eno1
macAddress: "aa:bb:cc:dd:ee:02"
- name: ens3f0
macAddress: "aa:bb:cc:dd:ee:20"
- name: ens3f1
macAddress: "aa:bb:cc:dd:ee:21"
networkConfig:
interfaces:
- name: eno1
type: ethernet
state: up
ipv4:
enabled: true
dhcp: true
sr-iov:
devices:
- name: ens3f0
devicesByPath:
- /dev/pci/0000:65:00.0
numVfs: 8
- name: ens3f1
devicesByPath:
- /dev/pci/0000:65:00.1
numVfs: 8Step 3: Corresponding SriovNetworkNodePolicy
After cluster installation, create a SriovNetworkNodePolicy that also uses PCI address selection:
apiVersion: sriovnetwork.openshift.io/v1
kind: SriovNetworkNodePolicy
metadata:
name: gpu-rdma-policy
namespace: openshift-sriov-network-operator
spec:
resourceName: rdmavfs
nodeSelector:
node-role.kubernetes.io/worker: ""
numVfs: 8
nicSelector:
pfNames:
- ens3f0#0-3
deviceID: "101e"
vendor: "15b3"
rootDevices:
- "0000:65:00.0"
deviceType: netdevice
isRdma: trueThe rootDevices field in nicSelector mirrors the PCI path approach — it anchors the policy to the physical slot.
Step 4: Verify VF Creation
After the policy applies and nodes reboot:
# Check VFs were created on the correct PCI device
oc debug node/worker-0 -- chroot /host \
ls /sys/bus/pci/devices/0000:65:00.0/virtfn*# Verify SR-IOV node state
oc get sriovnetworknodestates -n openshift-sriov-network-operator worker-0 \
-o jsonpath='{.status.interfaces}' | jq '.[] | select(.pciAddress=="0000:65:00.0")'Expected output:
{
"deviceID": "101e",
"driver": "mlx5_core",
"linkSpeed": "200 Gb/s",
"linkType": "ETH",
"mac": "aa:bb:cc:dd:ee:10",
"mtu": 9000,
"name": "ens3f0",
"numVfs": 8,
"pciAddress": "0000:65:00.0",
"totalvfs": 8,
"vendor": "15b3",
"vfs": [
{
"deviceID": "101f",
"driver": "mlx5_core",
"pciAddress": "0000:65:00.2",
"vendor": "15b3",
"vfID": 0
}
]
}Step 5: Validate Across Multiple Nodes
Ensure every node got the same PCI-anchored VFs:
# Loop through all workers
for node in $(oc get nodes -l node-role.kubernetes.io/worker -o name); do
echo "=== $node ==="
oc get sriovnetworknodestates -n openshift-sriov-network-operator \
$(basename $node) \
-o jsonpath='{range .status.interfaces[*]}{.pciAddress} {.name} VFs={.numVfs}{"\n"}{end}'
doneCommon Issues
PCI address differs between nodes of the same hardware model Even identical servers can have different PCI topologies if BIOS settings differ. Always discover the actual PCI address per node rather than assuming uniformity.
# Compare PCI topology across nodes
for node in worker-0 worker-1 worker-2; do
echo "=== $node ==="
oc debug node/$node -- chroot /host lspci | grep -i mellanox
doneVFs created on wrong NIC when using interface names only This is the exact problem devicesByPath solves. If you see VFs on an unexpected interface, switch from pfNames to rootDevices in your SriovNetworkNodePolicy.
agent-config.yaml ignored during assisted installer The sr-iov section in networkConfig is only processed during agent-based installations. For assisted installer deployments, configure SR-IOV post-install via SriovNetworkNodePolicy.
Device path format mismatch The path must follow the format /dev/pci/DDDD:BB:DD.F (domain:bus:device.function). A common mistake is omitting the domain prefix (0000:).
Best Practices
- Always use PCI paths for production: Interface names are convenient for lab setups but unreliable at scale
- Document the PCI topology: Maintain a mapping table of node → slot → PCI address → interface for each hardware generation
- Pin BIOS PCI enumeration order: Enable “Deterministic PCI Enumeration” in BIOS if available
- Use
rootDevicesin SriovNetworkNodePolicy: Even ifagent-config.yamluseddevicesByPath, the day-2 policy should also anchor to PCI address - Test after BIOS updates: PCI addresses can shift after firmware upgrades — always verify before and after
- Separate management and data NICs: Keep SR-IOV VFs on dedicated data-plane NICs, not the management interface
Key Takeaways
devicesByPathinagent-config.yamlselects NICs by PCI bus address for deterministic VF creation- PCI paths survive reboots, OS upgrades, and driver changes — interface names may not
- Mirror the PCI-based selection in
SriovNetworkNodePolicyusingrootDevicesfor day-2 consistency - Always discover actual PCI addresses per node — don’t assume identical hardware means identical paths
- Combine with
identify-mellanox-nic-modelsandcheck-bonding-and-interface-statusrecipes for a complete SR-IOV deployment workflow

Recommended
Kubernetes Recipes — The Complete Book100+ production-ready patterns with detailed explanations, best practices, and copy-paste YAML. Everything in one place.
Get the Book →Learn by Doing
CopyPasteLearn — Hands-on Cloud & DevOps CoursesMaster Kubernetes, Ansible, Terraform, and MLOps with interactive, copy-paste-run lessons. Start free.
Browse Courses →🎓 Deepen Your Skills — Hands-on Courses
Courses by CopyPasteLearn.com — Learn IT by Doing