Networking advanced ⏱ 30 minutes K8s 1.28+

DCB on Mellanox ConnectX: Lossless Ethernet...

Configure Data Center Bridging (DCB) on Mellanox ConnectX NICs. DCBX negotiation, PFC, ETS, and CN for lossless RoCE Ethernet in Kubernetes AI clusters.

By Luca Berton β€’ β€’ πŸ“– 9 min read

πŸ’‘ Quick Answer: DCB (Data Center Bridging) is a set of IEEE standards that make Ethernet lossless: PFC (802.1Qbb) pauses specific priorities, ETS (802.1Qaz) allocates bandwidth per traffic class, and DCBX auto-negotiates settings between NIC and switch. On Mellanox ConnectX, enable DCB with mlnx_qos for PFC/ETS and configure DCBX mode with lldptool or let firmware auto-negotiate. All three must be configured for production RoCE.

The Problem

Standard Ethernet is best-effort β€” it drops packets when buffers fill. RDMA/RoCE requires guaranteed delivery. DCB adds three capabilities to Ethernet to make it behave like InfiniBand:

StandardNameWhat It Does
IEEE 802.1QbbPFC (Priority Flow Control)Pauses specific traffic classes to prevent drops
IEEE 802.1QazETS (Enhanced Transmission Selection)Guarantees bandwidth per traffic class
IEEE 802.1QazDCBX (DCB Exchange)Auto-negotiates PFC/ETS between NIC and switch
IEEE 802.1QauCN (Congestion Notification) / ECNSignals congestion before buffers fill
flowchart TB
    subgraph DCB["Data Center Bridging Stack"]
        DCBX["DCBX<br/>(Auto-negotiation)"]
        PFC["PFC<br/>(Lossless priorities)"]
        ETS["ETS<br/>(Bandwidth allocation)"]
        CN["CN/ECN<br/>(Congestion signaling)"]
    end
    
    DCBX -->|"Negotiates"| PFC
    DCBX -->|"Negotiates"| ETS
    CN -->|"Reduces"| PFC
    
    subgraph RESULT["Result"]
        LOSSLESS["Lossless Ethernet<br/>for RoCE/RDMA"]
    end
    
    PFC --> LOSSLESS
    ETS --> LOSSLESS
    CN --> LOSSLESS

DCB Components Explained

PFC: Priority Flow Control

PFC extends IEEE 802.3x PAUSE to work per-priority (8 priorities, 0-7). Only the lossless priority pauses; other traffic continues flowing.

Without PFC:  ALL traffic pauses (802.3x global PAUSE)
With PFC:     Only priority 3 pauses β†’ RoCE lossless, SSH/management unaffected

ETS: Enhanced Transmission Selection

ETS guarantees minimum bandwidth per traffic class and defines scheduling:

TC0 (Best Effort):  70% bandwidth, ETS scheduling
TC3 (RoCE/RDMA):    30% bandwidth, ETS scheduling
TC1-2, TC4-7:       Strict priority (served immediately when queued)

DCBX: DCB Exchange Protocol

DCBX runs over LLDP to synchronize PFC/ETS settings between NIC and switch automatically:

DCBX VersionStandardNotes
CEE (pre-standard)Cisco/IntelLegacy, avoid
IEEE 802.1QazIEEE standardUse this
AutoAuto-detectTries IEEE first, falls back to CEE

Step-by-Step DCB Configuration

Step 1: Check DCB Firmware Capability

# Verify firmware supports DCB
ethtool -i ens8f0np0
# driver: mlx5_core
# firmware-version: 28.39.1002

# Check DCB capability
ethtool --show-features ens8f0np0 | grep dcb
# DCB: on

# If DCB is off:
ethtool --set-features ens8f0np0 dcb on

Step 2: Configure DCBX Mode

# Option A: Using lldptool (recommended for DCBX control)
# Install lldpad daemon
yum install -y lldpad    # RHEL
apt install -y lldpad    # Ubuntu

systemctl enable --now lldpad

# Set DCBX to IEEE mode
lldptool -T -i ens8f0np0 -V IEEE-DCBX mode=reset
lldptool set-lldp -i ens8f0np0 adminStatus=rxtx

# Configure PFC via DCBX (advertise priority 3 as lossless)
lldptool -T -i ens8f0np0 -V PFC enabled=3
# This tells the switch: "I want priority 3 to be lossless"

# Configure ETS via DCBX
lldptool -T -i ens8f0np0 -V ETS-CFG \
  tsa=0:ets,1:strict,2:strict,3:ets,4:strict,5:strict,6:strict,7:strict \
  up2tc=0:0,1:1,2:2,3:3,4:4,5:5,6:6,7:7 \
  tcbw=70,0,0,30,0,0,0,0

# Verify DCBX state
lldptool -t -i ens8f0np0 -V PFC
lldptool -t -i ens8f0np0 -V ETS-CFG
# Option B: Disable DCBX, configure manually with mlnx_qos
# (Use when switch doesn't support DCBX or you want static config)
mlnx_qos -i ens8f0np0 --trust dscp
mlnx_qos -i ens8f0np0 --pfc 0,0,0,1,0,0,0,0
mlnx_qos -i ens8f0np0 --tc_bw 70,0,0,30,0,0,0,0 \
  --tsa ets,strict,strict,ets,strict,strict,strict,strict

Step 3: Verify DCB Negotiation

# Check if DCBX negotiated successfully
lldptool -t -i ens8f0np0 -V IEEE-DCBX -c mode
# mode = IEEE

# Check PFC willing/status
lldptool -t -i ens8f0np0 -V PFC -c willing
# willing=yes    ← NIC will accept switch's PFC config

lldptool -t -i ens8f0np0 -V PFC -c enabled
# enabled=3      ← Priority 3 is lossless

# Check what the switch is advertising
lldptool -n -t -i ens8f0np0 -V PFC
# enabled=3      ← Switch also says priority 3 is lossless βœ…

# Check ETS negotiation
lldptool -n -t -i ens8f0np0 -V ETS-CFG
# Shows switch's ETS configuration

Step 4: Linux DCB Tools (Alternative)

The dcb command (from iproute2) is another way to configure DCB on Linux:

# Show DCB state
dcb ets show dev ens8f0np0
# tc-tsa: 0:ets 1:strict 2:strict 3:ets 4:strict 5:strict 6:strict 7:strict
# tc-bw:  70 0 0 30 0 0 0 0
# pg-bw:  70 0 0 30 0 0 0 0

dcb pfc show dev ens8f0np0
# pfc-cap 8 macsec-bypass off delay 0
# prio-pfc 0:off 1:off 2:off 3:on 4:off 5:off 6:off 7:off

# Set PFC via dcb tool
dcb pfc set dev ens8f0np0 prio-pfc 0:off 1:off 2:off 3:on 4:off 5:off 6:off 7:off

# Set ETS via dcb tool
dcb ets set dev ens8f0np0 \
  tc-tsa 0:ets 3:ets \
  tc-bw 0:70 3:30

# Show DCBX mode
dcb dcbx show dev ens8f0np0
# host firmware

Step 5: Verify End-to-End

#!/bin/bash
# dcb-verify.sh β€” Full DCB health check for Mellanox NIC
IFACE=${1:-ens8f0np0}

echo "=== DCB Feature ==="
ethtool --show-features "$IFACE" | grep dcb

echo -e "\n=== Trust Mode ==="
mlnx_qos -i "$IFACE" 2>/dev/null | grep -i trust

echo -e "\n=== PFC State ==="
mlnx_qos -i "$IFACE" 2>/dev/null | grep -A2 "PFC"

echo -e "\n=== ETS State ==="
mlnx_qos -i "$IFACE" 2>/dev/null | grep -A3 "tc:"

echo -e "\n=== PFC Counters (Priority 3) ==="
ethtool -S "$IFACE" | grep prio3
# Non-zero pause = PFC active
# Non-zero discard = PROBLEM

echo -e "\n=== DCBX Negotiation ==="
if command -v lldptool &>/dev/null; then
    echo "Local PFC:"
    lldptool -t -i "$IFACE" -V PFC -c enabled 2>/dev/null
    echo "Peer PFC:"
    lldptool -n -t -i "$IFACE" -V PFC -c enabled 2>/dev/null
    echo "DCBX mode:"
    lldptool -t -i "$IFACE" -V IEEE-DCBX -c mode 2>/dev/null
else
    echo "lldptool not installed β€” DCBX status unavailable"
    dcb dcbx show dev "$IFACE" 2>/dev/null
fi

echo -e "\n=== RoCE Mode ==="
cma_roce_mode -d mlx5_0 2>/dev/null || echo "cma_roce_mode not found"

echo -e "\n=== ECN State (TC3) ==="
for type in roce_np roce_rp; do
    val=$(cat /sys/class/net/"$IFACE"/ecn/${type}/enable/3 2>/dev/null || echo "N/A")
    echo "$type: $val"
done

echo -e "\n=== RDMA Devices ==="
rdma link show 2>/dev/null | grep "$IFACE"

echo ""
echo "=== Summary ==="
PFC_OK=$(mlnx_qos -i "$IFACE" 2>/dev/null | grep -A1 "enabled:" | tail -1 | awk '{print $4}')
TRUST_OK=$(mlnx_qos -i "$IFACE" 2>/dev/null | grep -i trust | grep -c dscp)
DROPS=$(ethtool -S "$IFACE" 2>/dev/null | grep "prio3_discard" | awk '{print $2}')

[[ "$PFC_OK" == "1" ]] && echo "βœ… PFC enabled on priority 3" || echo "❌ PFC NOT enabled on priority 3"
[[ "$TRUST_OK" -gt 0 ]] && echo "βœ… DSCP trust mode" || echo "❌ Not in DSCP trust mode"
[[ "${DROPS:-0}" == "0" ]] && echo "βœ… Zero drops on priority 3" || echo "❌ Drops detected on priority 3: $DROPS"

DCBX: Willing vs Non-Willing

ModeBehaviorUse When
WillingNIC accepts switch’s PFC/ETS configSwitch is the source of truth (recommended)
Non-willingNIC pushes its config to switchNIC is the source of truth (rare)
# Set NIC to willing mode (accept switch config)
lldptool -T -i ens8f0np0 -V PFC willing=yes
lldptool -T -i ens8f0np0 -V ETS-CFG willing=yes

# Set NIC to non-willing (push config to switch)
lldptool -T -i ens8f0np0 -V PFC willing=no

Recommendation: Use willing mode. Configure PFC/ETS on the switch, let DCBX push settings to NICs automatically. This ensures consistency across all ports.

Kubernetes: Automate DCB with MachineConfig

apiVersion: machineconfiguration.openshift.io/v1
kind: MachineConfig
metadata:
  name: 99-dcb-lossless-roce
  labels:
    machineconfiguration.openshift.io/role: worker
spec:
  config:
    ignition:
      version: 3.4.0
    systemd:
      units:
        - name: dcb-config.service
          enabled: true
          contents: |
            [Unit]
            Description=Configure DCB for lossless RoCE
            After=network-online.target
            Wants=network-online.target
            [Service]
            Type=oneshot
            RemainAfterExit=yes
            ExecStart=/usr/local/bin/configure-dcb.sh
            [Install]
            WantedBy=multi-user.target
    storage:
      files:
        - path: /usr/local/bin/configure-dcb.sh
          mode: 0755
          contents:
            inline: |
              #!/bin/bash
              set -euo pipefail
              for iface in $(ls /sys/class/net/); do
                if ethtool -i "$iface" 2>/dev/null | grep -q mlx5_core; then
                  echo "Configuring DCB on $iface"
                  # Trust DSCP
                  mlnx_qos -i "$iface" --trust dscp
                  # PFC on priority 3
                  mlnx_qos -i "$iface" --pfc 0,0,0,1,0,0,0,0
                  # ETS: 70% best-effort, 30% RoCE
                  mlnx_qos -i "$iface" \
                    --tc_bw 70,0,0,30,0,0,0,0 \
                    --tsa ets,strict,strict,ets,strict,strict,strict,strict
                  # ECN on TC3
                  echo 1 > /sys/class/net/"$iface"/ecn/roce_np/enable/3 2>/dev/null || true
                  echo 1 > /sys/class/net/"$iface"/ecn/roce_rp/enable/3 2>/dev/null || true
                fi
              done

Common Issues

IssueCauseFix
DCBX not negotiatinglldpad not running or switch LLDP disabledsystemctl start lldpad, enable LLDP on switch
PFC mismatch between NIC and switchDifferent willing modesSet NIC willing=yes, configure PFC on switch
CEE vs IEEE mismatchNIC in IEEE, switch in CEE (or vice versa)Set both to IEEE or use DCBX auto mode
ETS bandwidth not enforcedWrong tsa modeUse ets not strict for bandwidth-limited TCs
dcb command not foundOld iproute2Update iproute2 package or use mlnx_qos
PFC storms / head-of-line blockingCongestion loopEnable ECN, increase switch buffers, check for slow receivers

Best Practices

  • Use DCBX IEEE mode β€” standard, supported by all modern switches
  • Switch as source of truth β€” configure on switch, NIC in willing mode
  • PFC on priority 3 only β€” only RoCE needs lossless
  • ECN always alongside PFC β€” prevents PFC storms
  • Monitor PFC counters β€” high pause counts signal congestion
  • ETS guarantees bandwidth β€” don’t rely on strict priority for RDMA (starves other traffic)
  • Test with ib_write_bw β€” verify lossless RDMA before deploying AI workloads
  • Persist with MachineConfig β€” mlnx_qos is volatile

Key Takeaways

  • DCB = PFC + ETS + DCBX β€” together they make Ethernet lossless
  • DCBX auto-negotiates PFC/ETS between NIC and switch over LLDP
  • Configure with mlnx_qos (Mellanox-specific) or dcb (Linux generic) or lldptool (DCBX)
  • Willing mode on NIC + switch-driven config = consistent fleet-wide settings
  • PFC prevents drops, ETS guarantees bandwidth, ECN reduces PFC frequency
  • Must be configured end-to-end: NIC ↔ every switch hop ↔ NIC
#dcb #dcbx #pfc #ets #mellanox #connectx #lossless #roce
Luca Berton
Written by Luca Berton

Principal Solutions Architect specializing in Kubernetes, AI/GPU infrastructure, and cloud-native platforms. Author of Kubernetes Recipes and creator of CopyPasteLearn courses.

Kubernetes Recipes book cover

Want More Kubernetes Recipes?

This recipe is from Kubernetes Recipes, our 750-page practical guide with hundreds of production-ready patterns.

Luca Berton Ansible Pilot Ansible by Example Open Empower K8s Recipes Terraform Pilot CopyPasteLearn ProteinLens