DCB on Mellanox ConnectX for Lossless Ethernet
Configure Data Center Bridging (DCB) on Mellanox ConnectX NICs. DCBX negotiation, PFC, ETS, and CN for lossless RoCE Ethernet in Kubernetes AI clusters.
π‘ Quick Answer: DCB (Data Center Bridging) is a set of IEEE standards that make Ethernet lossless: PFC (802.1Qbb) pauses specific priorities, ETS (802.1Qaz) allocates bandwidth per traffic class, and DCBX auto-negotiates settings between NIC and switch. On Mellanox ConnectX, enable DCB with
mlnx_qosfor PFC/ETS and configure DCBX mode withlldptoolor let firmware auto-negotiate. All three must be configured for production RoCE.
The Problem
Standard Ethernet is best-effort β it drops packets when buffers fill. RDMA/RoCE requires guaranteed delivery. DCB adds three capabilities to Ethernet to make it behave like InfiniBand:
| Standard | Name | What It Does |
|---|---|---|
| IEEE 802.1Qbb | PFC (Priority Flow Control) | Pauses specific traffic classes to prevent drops |
| IEEE 802.1Qaz | ETS (Enhanced Transmission Selection) | Guarantees bandwidth per traffic class |
| IEEE 802.1Qaz | DCBX (DCB Exchange) | Auto-negotiates PFC/ETS between NIC and switch |
| IEEE 802.1Qau | CN (Congestion Notification) / ECN | Signals congestion before buffers fill |
flowchart TB
subgraph DCB["Data Center Bridging Stack"]
DCBX["DCBX<br/>(Auto-negotiation)"]
PFC["PFC<br/>(Lossless priorities)"]
ETS["ETS<br/>(Bandwidth allocation)"]
CN["CN/ECN<br/>(Congestion signaling)"]
end
DCBX -->|"Negotiates"| PFC
DCBX -->|"Negotiates"| ETS
CN -->|"Reduces"| PFC
subgraph RESULT["Result"]
LOSSLESS["Lossless Ethernet<br/>for RoCE/RDMA"]
end
PFC --> LOSSLESS
ETS --> LOSSLESS
CN --> LOSSLESSDCB Components Explained
PFC: Priority Flow Control
PFC extends IEEE 802.3x PAUSE to work per-priority (8 priorities, 0-7). Only the lossless priority pauses; other traffic continues flowing.
Without PFC: ALL traffic pauses (802.3x global PAUSE)
With PFC: Only priority 3 pauses β RoCE lossless, SSH/management unaffectedETS: Enhanced Transmission Selection
ETS guarantees minimum bandwidth per traffic class and defines scheduling:
TC0 (Best Effort): 70% bandwidth, ETS scheduling
TC3 (RoCE/RDMA): 30% bandwidth, ETS scheduling
TC1-2, TC4-7: Strict priority (served immediately when queued)DCBX: DCB Exchange Protocol
DCBX runs over LLDP to synchronize PFC/ETS settings between NIC and switch automatically:
| DCBX Version | Standard | Notes |
|---|---|---|
| CEE (pre-standard) | Cisco/Intel | Legacy, avoid |
| IEEE 802.1Qaz | IEEE standard | Use this |
| Auto | Auto-detect | Tries IEEE first, falls back to CEE |
Step-by-Step DCB Configuration
Step 1: Check DCB Firmware Capability
# Verify firmware supports DCB
ethtool -i ens8f0np0
# driver: mlx5_core
# firmware-version: 28.39.1002
# Check DCB capability
ethtool --show-features ens8f0np0 | grep dcb
# DCB: on
# If DCB is off:
ethtool --set-features ens8f0np0 dcb onStep 2: Configure DCBX Mode
# Option A: Using lldptool (recommended for DCBX control)
# Install lldpad daemon
yum install -y lldpad # RHEL
apt install -y lldpad # Ubuntu
systemctl enable --now lldpad
# Set DCBX to IEEE mode
lldptool -T -i ens8f0np0 -V IEEE-DCBX mode=reset
lldptool set-lldp -i ens8f0np0 adminStatus=rxtx
# Configure PFC via DCBX (advertise priority 3 as lossless)
lldptool -T -i ens8f0np0 -V PFC enabled=3
# This tells the switch: "I want priority 3 to be lossless"
# Configure ETS via DCBX
lldptool -T -i ens8f0np0 -V ETS-CFG \
tsa=0:ets,1:strict,2:strict,3:ets,4:strict,5:strict,6:strict,7:strict \
up2tc=0:0,1:1,2:2,3:3,4:4,5:5,6:6,7:7 \
tcbw=70,0,0,30,0,0,0,0
# Verify DCBX state
lldptool -t -i ens8f0np0 -V PFC
lldptool -t -i ens8f0np0 -V ETS-CFG# Option B: Disable DCBX, configure manually with mlnx_qos
# (Use when switch doesn't support DCBX or you want static config)
mlnx_qos -i ens8f0np0 --trust dscp
mlnx_qos -i ens8f0np0 --pfc 0,0,0,1,0,0,0,0
mlnx_qos -i ens8f0np0 --tc_bw 70,0,0,30,0,0,0,0 \
--tsa ets,strict,strict,ets,strict,strict,strict,strictStep 3: Verify DCB Negotiation
# Check if DCBX negotiated successfully
lldptool -t -i ens8f0np0 -V IEEE-DCBX -c mode
# mode = IEEE
# Check PFC willing/status
lldptool -t -i ens8f0np0 -V PFC -c willing
# willing=yes β NIC will accept switch's PFC config
lldptool -t -i ens8f0np0 -V PFC -c enabled
# enabled=3 β Priority 3 is lossless
# Check what the switch is advertising
lldptool -n -t -i ens8f0np0 -V PFC
# enabled=3 β Switch also says priority 3 is lossless β
# Check ETS negotiation
lldptool -n -t -i ens8f0np0 -V ETS-CFG
# Shows switch's ETS configurationStep 4: Linux DCB Tools (Alternative)
The dcb command (from iproute2) is another way to configure DCB on Linux:
# Show DCB state
dcb ets show dev ens8f0np0
# tc-tsa: 0:ets 1:strict 2:strict 3:ets 4:strict 5:strict 6:strict 7:strict
# tc-bw: 70 0 0 30 0 0 0 0
# pg-bw: 70 0 0 30 0 0 0 0
dcb pfc show dev ens8f0np0
# pfc-cap 8 macsec-bypass off delay 0
# prio-pfc 0:off 1:off 2:off 3:on 4:off 5:off 6:off 7:off
# Set PFC via dcb tool
dcb pfc set dev ens8f0np0 prio-pfc 0:off 1:off 2:off 3:on 4:off 5:off 6:off 7:off
# Set ETS via dcb tool
dcb ets set dev ens8f0np0 \
tc-tsa 0:ets 3:ets \
tc-bw 0:70 3:30
# Show DCBX mode
dcb dcbx show dev ens8f0np0
# host firmwareStep 5: Verify End-to-End
#!/bin/bash
# dcb-verify.sh β Full DCB health check for Mellanox NIC
IFACE=${1:-ens8f0np0}
echo "=== DCB Feature ==="
ethtool --show-features "$IFACE" | grep dcb
echo -e "\n=== Trust Mode ==="
mlnx_qos -i "$IFACE" 2>/dev/null | grep -i trust
echo -e "\n=== PFC State ==="
mlnx_qos -i "$IFACE" 2>/dev/null | grep -A2 "PFC"
echo -e "\n=== ETS State ==="
mlnx_qos -i "$IFACE" 2>/dev/null | grep -A3 "tc:"
echo -e "\n=== PFC Counters (Priority 3) ==="
ethtool -S "$IFACE" | grep prio3
# Non-zero pause = PFC active
# Non-zero discard = PROBLEM
echo -e "\n=== DCBX Negotiation ==="
if command -v lldptool &>/dev/null; then
echo "Local PFC:"
lldptool -t -i "$IFACE" -V PFC -c enabled 2>/dev/null
echo "Peer PFC:"
lldptool -n -t -i "$IFACE" -V PFC -c enabled 2>/dev/null
echo "DCBX mode:"
lldptool -t -i "$IFACE" -V IEEE-DCBX -c mode 2>/dev/null
else
echo "lldptool not installed β DCBX status unavailable"
dcb dcbx show dev "$IFACE" 2>/dev/null
fi
echo -e "\n=== RoCE Mode ==="
cma_roce_mode -d mlx5_0 2>/dev/null || echo "cma_roce_mode not found"
echo -e "\n=== ECN State (TC3) ==="
for type in roce_np roce_rp; do
val=$(cat /sys/class/net/"$IFACE"/ecn/${type}/enable/3 2>/dev/null || echo "N/A")
echo "$type: $val"
done
echo -e "\n=== RDMA Devices ==="
rdma link show 2>/dev/null | grep "$IFACE"
echo ""
echo "=== Summary ==="
PFC_OK=$(mlnx_qos -i "$IFACE" 2>/dev/null | grep -A1 "enabled:" | tail -1 | awk '{print $4}')
TRUST_OK=$(mlnx_qos -i "$IFACE" 2>/dev/null | grep -i trust | grep -c dscp)
DROPS=$(ethtool -S "$IFACE" 2>/dev/null | grep "prio3_discard" | awk '{print $2}')
[[ "$PFC_OK" == "1" ]] && echo "β
PFC enabled on priority 3" || echo "β PFC NOT enabled on priority 3"
[[ "$TRUST_OK" -gt 0 ]] && echo "β
DSCP trust mode" || echo "β Not in DSCP trust mode"
[[ "${DROPS:-0}" == "0" ]] && echo "β
Zero drops on priority 3" || echo "β Drops detected on priority 3: $DROPS"DCBX: Willing vs Non-Willing
| Mode | Behavior | Use When |
|---|---|---|
| Willing | NIC accepts switchβs PFC/ETS config | Switch is the source of truth (recommended) |
| Non-willing | NIC pushes its config to switch | NIC is the source of truth (rare) |
# Set NIC to willing mode (accept switch config)
lldptool -T -i ens8f0np0 -V PFC willing=yes
lldptool -T -i ens8f0np0 -V ETS-CFG willing=yes
# Set NIC to non-willing (push config to switch)
lldptool -T -i ens8f0np0 -V PFC willing=noRecommendation: Use willing mode. Configure PFC/ETS on the switch, let DCBX push settings to NICs automatically. This ensures consistency across all ports.
Kubernetes: Automate DCB with MachineConfig
apiVersion: machineconfiguration.openshift.io/v1
kind: MachineConfig
metadata:
name: 99-dcb-lossless-roce
labels:
machineconfiguration.openshift.io/role: worker
spec:
config:
ignition:
version: 3.4.0
systemd:
units:
- name: dcb-config.service
enabled: true
contents: |
[Unit]
Description=Configure DCB for lossless RoCE
After=network-online.target
Wants=network-online.target
[Service]
Type=oneshot
RemainAfterExit=yes
ExecStart=/usr/local/bin/configure-dcb.sh
[Install]
WantedBy=multi-user.target
storage:
files:
- path: /usr/local/bin/configure-dcb.sh
mode: 0755
contents:
inline: |
#!/bin/bash
set -euo pipefail
for iface in $(ls /sys/class/net/); do
if ethtool -i "$iface" 2>/dev/null | grep -q mlx5_core; then
echo "Configuring DCB on $iface"
# Trust DSCP
mlnx_qos -i "$iface" --trust dscp
# PFC on priority 3
mlnx_qos -i "$iface" --pfc 0,0,0,1,0,0,0,0
# ETS: 70% best-effort, 30% RoCE
mlnx_qos -i "$iface" \
--tc_bw 70,0,0,30,0,0,0,0 \
--tsa ets,strict,strict,ets,strict,strict,strict,strict
# ECN on TC3
echo 1 > /sys/class/net/"$iface"/ecn/roce_np/enable/3 2>/dev/null || true
echo 1 > /sys/class/net/"$iface"/ecn/roce_rp/enable/3 2>/dev/null || true
fi
doneCommon Issues
| Issue | Cause | Fix |
|---|---|---|
| DCBX not negotiating | lldpad not running or switch LLDP disabled | systemctl start lldpad, enable LLDP on switch |
| PFC mismatch between NIC and switch | Different willing modes | Set NIC willing=yes, configure PFC on switch |
| CEE vs IEEE mismatch | NIC in IEEE, switch in CEE (or vice versa) | Set both to IEEE or use DCBX auto mode |
| ETS bandwidth not enforced | Wrong tsa mode | Use ets not strict for bandwidth-limited TCs |
dcb command not found | Old iproute2 | Update iproute2 package or use mlnx_qos |
| PFC storms / head-of-line blocking | Congestion loop | Enable ECN, increase switch buffers, check for slow receivers |
Best Practices
- Use DCBX IEEE mode β standard, supported by all modern switches
- Switch as source of truth β configure on switch, NIC in willing mode
- PFC on priority 3 only β only RoCE needs lossless
- ECN always alongside PFC β prevents PFC storms
- Monitor PFC counters β high pause counts signal congestion
- ETS guarantees bandwidth β donβt rely on strict priority for RDMA (starves other traffic)
- Test with ib_write_bw β verify lossless RDMA before deploying AI workloads
- Persist with MachineConfig β mlnx_qos is volatile
Key Takeaways
- DCB = PFC + ETS + DCBX β together they make Ethernet lossless
- DCBX auto-negotiates PFC/ETS between NIC and switch over LLDP
- Configure with
mlnx_qos(Mellanox-specific) ordcb(Linux generic) orlldptool(DCBX) - Willing mode on NIC + switch-driven config = consistent fleet-wide settings
- PFC prevents drops, ETS guarantees bandwidth, ECN reduces PFC frequency
- Must be configured end-to-end: NIC β every switch hop β NIC

Recommended