ECN MachineConfig OpenShift Nodes
Enable ECN (Explicit Congestion Notification) on OpenShift nodes via MachineConfig for lossless RoCEv2 RDMA networking. Sysctl and Mellanox NIC configuration.
π‘ Quick Answer: Create a MachineConfig with
99-ecn-enablethat setsnet.ipv4.tcp_ecn=1via sysctl to enable ECN negotiation on OpenShift nodes. For RoCEv2 RDMA, also configure Mellanox NIC ECN parameters viamlnx_qosor NetworkManager dispatcher scripts.
The Problem
ECN (Explicit Congestion Notification) allows switches to signal congestion to endpoints without dropping packets. For RoCEv2 RDMA workloads:
- Without ECN, congestion triggers PFC pause frames which halt ALL traffic on the link
- With ECN, the NIC receives congestion signals and reduces its sending rate proactively
- ECN operates at microsecond granularity vs PFCβs nanosecond emergency braking
- Together, ECN + PFC provide a two-tier lossless fabric: ECN prevents congestion, PFC prevents drops
Linux kernels have ECN disabled by default (tcp_ecn=2 = negotiate only if requested). For RDMA nodes, you must enable it explicitly.
The Solution
MachineConfig for ECN Sysctl
apiVersion: machineconfiguration.openshift.io/v1
kind: MachineConfig
metadata:
labels:
machineconfiguration.openshift.io/role: worker
name: 99-ecn-enable
spec:
config:
ignition:
version: 3.4.0
storage:
files:
- path: /etc/sysctl.d/99-ecn.conf
mode: 0644
overwrite: true
contents:
source: data:text/plain;charset=utf-8;base64,IyBFbmFibGUgRUNOIG5lZ290aWF0aW9uIGZvciBSb0NFdjIgUkRNQQojIDAgPSBkaXNhYmxlZCwgMSA9IGVuYWJsZSwgMiA9IG5lZ290aWF0ZS1vbmx5CiMgU2V0IHRvIDEgZm9yIEdQVSBub2RlcyB3aXRoIFJETUEgbmV0d29ya2luZwpuZXQuaXB2NC50Y3BfZWNuPTEKbmV0LmlwdjQudGNwX2Vjbl9mYWxsYmFjaz0xCg==The base64 content decodes to:
# Enable ECN negotiation for RoCEv2 RDMA
# 0 = disabled, 1 = enable, 2 = negotiate-only
# Set to 1 for GPU nodes with RDMA networking
net.ipv4.tcp_ecn=1
net.ipv4.tcp_ecn_fallback=1Generate the base64 yourself:
cat <<'EOF' | base64 -w0
# Enable ECN negotiation for RoCEv2 RDMA
# 0 = disabled, 1 = enable, 2 = negotiate-only
# Set to 1 for GPU nodes with RDMA networking
net.ipv4.tcp_ecn=1
net.ipv4.tcp_ecn_fallback=1
EOFTarget GPU Nodes Only with MCP
If only GPU workers need ECN, create a dedicated MachineConfigPool:
apiVersion: machineconfiguration.openshift.io/v1
kind: MachineConfigPool
metadata:
name: gpu-worker
spec:
machineConfigSelector:
matchExpressions:
- key: machineconfiguration.openshift.io/role
operator: In
values: [worker, gpu-worker]
nodeSelector:
matchLabels:
node-role.kubernetes.io/gpu-worker: ""Then label the MachineConfig for gpu-worker:
metadata:
labels:
machineconfiguration.openshift.io/role: gpu-worker
name: 99-ecn-enableMellanox NIC ECN Configuration
Kernel sysctl enables ECN at the TCP/IP level. For RoCEv2, the Mellanox NIC also needs ECN configuration:
apiVersion: machineconfiguration.openshift.io/v1
kind: MachineConfig
metadata:
labels:
machineconfiguration.openshift.io/role: gpu-worker
name: 99-mlnx-ecn-config
spec:
config:
ignition:
version: 3.4.0
storage:
files:
- path: /etc/NetworkManager/dispatcher.d/99-mlnx-ecn.sh
mode: 0755
overwrite: true
contents:
source: data:text/plain;charset=utf-8,#!/bin/bash%0A%23 Configure Mellanox NIC ECN parameters for RoCEv2%0A%23 Runs on interface up events%0A%0AINTERFACE=%241%0AACTION=%242%0A%0Aif [ "%24ACTION" != "up" ]; then exit 0; fi%0A%0A%23 Only configure RDMA-capable interfaces%0Acase %24INTERFACE in%0A ens*f0|ens*f1|enp*)%0A %23 Enable ECN on the NIC (if mlnx_qos available)%0A if command -v mlnx_qos %26>/dev/null; then%0A mlnx_qos -i %24INTERFACE --ecn 0,0,0,1,0,0,0,0%0A fi%0A %0A %23 Set DSCP trust mode%0A if command -v mlnx_qos %26>/dev/null; then%0A mlnx_qos -i %24INTERFACE --trust dscp%0A fi%0A ;;%0Aesac%0AOr use a MOFED container DaemonSet for fleet-wide NIC configuration (see related recipe: mlnx-qos MOFED container guide).
PFC on Mellanox NIC via MachineConfig
Complete the lossless stack β PFC + ECN together:
apiVersion: machineconfiguration.openshift.io/v1
kind: MachineConfig
metadata:
labels:
machineconfiguration.openshift.io/role: gpu-worker
name: 99-roce-lossless
spec:
config:
ignition:
version: 3.4.0
storage:
files:
- path: /etc/sysctl.d/99-ecn.conf
mode: 0644
overwrite: true
contents:
source: data:text/plain;charset=utf-8,net.ipv4.tcp_ecn=1%0Anet.ipv4.tcp_ecn_fallback=1%0A
- path: /usr/local/bin/configure-roce.sh
mode: 0755
overwrite: true
contents:
source: data:text/plain;charset=utf-8,#!/bin/bash%0Aset -euo pipefail%0A%0A%23 Configure all Mellanox interfaces for lossless RoCEv2%0Afor dev in /sys/class/infiniband/mlx5_*; do%0A IBDEV=$(basename %24dev)%0A NETDEV=$(cat %24dev/device/net/*/operstate 2>/dev/null | head -1 || true)%0A %0A %23 Get the net device name%0A for nd in %24dev/device/net/*; do%0A NETDEV=$(basename %24nd)%0A break%0A done%0A %0A if [ -z "%24NETDEV" ]; then continue; fi%0A %0A echo "Configuring %24IBDEV (%24NETDEV) for lossless RoCEv2"%0A %0A %23 Trust DSCP markings%0A mlnx_qos -i %24NETDEV --trust dscp 2>/dev/null || true%0A %0A %23 Enable PFC on priority 3 only%0A mlnx_qos -i %24NETDEV --pfc 0,0,0,1,0,0,0,0 2>/dev/null || true%0A %0A %23 Enable ECN on priority 3 only%0A mlnx_qos -i %24NETDEV --ecn 0,0,0,1,0,0,0,0 2>/dev/null || true%0A %0A echo "Done: %24IBDEV (%24NETDEV) trust=dscp pfc=3 ecn=3"%0Adone%0A
systemd:
units:
- name: configure-roce.service
enabled: true
contents: |
[Unit]
Description=Configure Mellanox NICs for lossless RoCEv2
After=network-online.target
Wants=network-online.target
[Service]
Type=oneshot
ExecStart=/usr/local/bin/configure-roce.sh
RemainAfterExit=true
[Install]
WantedBy=multi-user.targetVerification
# Check ECN sysctl is applied
oc debug node/gpu-worker-0 -- chroot /host sysctl net.ipv4.tcp_ecn
# Should output: net.ipv4.tcp_ecn = 1
# Check MachineConfig rollout
oc get mcp gpu-worker
# UPDATED=True, DEGRADED=False
# Verify NIC ECN settings (requires MOFED tools)
oc debug node/gpu-worker-0 -- chroot /host mlnx_qos -i ens1f0 | grep -A1 ecn
# Check PFC counters
oc debug node/gpu-worker-0 -- chroot /host ethtool -S ens1f0 | grep pfc
# Verify DSCP trust
oc debug node/gpu-worker-0 -- chroot /host mlnx_qos -i ens1f0 | grep trustgraph TD
subgraph MachineConfig Stack
MC1[99-ecn-enable<br/>sysctl tcp_ecn=1] --> NODE[GPU Worker Node]
MC2[99-roce-lossless<br/>systemd + mlnx_qos] --> NODE
end
subgraph Node Configuration
NODE --> SYSCTL[sysctl<br/>tcp_ecn=1<br/>tcp_ecn_fallback=1]
NODE --> MLNX[mlnx_qos<br/>trust dscp<br/>pfc 0,0,0,1<br/>ecn 0,0,0,1]
end
subgraph Switch Side
SWITCH[Dell OS10<br/>PFC TC3<br/>ECN/WRED<br/>trust dscp]
end
MLNX <-->|Lossless RoCEv2| SWITCHCommon Issues
MachineConfig causes node to enter Degraded state
Check MachineConfig rendering:
oc get mcp gpu-worker -o jsonpath='{.status.conditions[?(@.type=="Degraded")]}'Common causes: invalid base64, missing ignition version, conflicting file paths.
ECN sysctl reverts after reboot
Ensure the file is under /etc/sysctl.d/ (persistent) not /proc/sys/ (ephemeral). MachineConfig handles this correctly.
mlnx_qos command not found on node
MOFED tools must be installed. Options:
- MOFED container DaemonSet (recommended β see related recipe)
- MachineConfig that installs MOFED RPMs (complex, version-coupled)
- GPU Operator with MOFED driver container
PFC and ECN both showing priority 0 instead of 3
Verify the --pfc and --ecn arguments use the correct bitmap position:
# Position: 0,1,2,3,4,5,6,7
# ^ ^
# Priority 3 is the 4th position (0-indexed)
mlnx_qos -i ens1f0 --pfc 0,0,0,1,0,0,0,0
mlnx_qos -i ens1f0 --ecn 0,0,0,1,0,0,0,0Best Practices
- Use
99-prefix for MachineConfig names β higher numbers take priority over lower - Target GPU nodes via dedicated MCP β donβt apply RDMA config to all workers
- Enable both ECN and PFC β ECN reduces congestion, PFC prevents drops; they complement each other
- Set
tcp_ecn_fallback=1β allows fallback to non-ECN if remote doesnβt support it - Use systemd oneshot service for NIC config β ensures it runs after network is up and persists across reboots
- Verify both ends: node ECN + switch ECN/WRED must both be configured
- Test with
ib_write_bwbefore and after β measure latency improvement from ECN activation - Monitor ECN counters:
ethtool -S ens1f0 | grep ecnβ increasingrx_ecn_markconfirms ECN is working
Key Takeaways
- ECN (
tcp_ecn=1) enables proactive congestion signaling before packet drops occur - MachineConfig is the correct way to set persistent sysctl on OpenShift nodes
- DSCP 26 (AF31) β Priority 3 is the RoCEv2 convention β both switch and host must agree
- PFC prevents drops (reactive), ECN prevents congestion (proactive) β use both
mlnx_qosconfigures NIC-level ECN/PFC β requires MOFED tools on the node- Dedicated MachineConfigPool for GPU workers prevents RDMA config from affecting non-GPU nodes
- NetworkManager dispatcher scripts run on interface up β good for NIC-level config
- Systemd oneshot services are more reliable for boot-time NIC configuration