Mellanox RoCE DSCP QoS DaemonSet
Deploy a DaemonSet that configures DSCP trust, PFC priority 3, and RoCE ToS 106 on all Mellanox PFs. Uses DOCA driver image with ibdev2netdev, mlnx_qos.
π‘ Quick Answer: Deploy a privileged DaemonSet using the DOCA driver image that waits for Mellanox driver readiness, then iterates over physical functions via
ibdev2netdevand appliesmlnx_qos --trust dscp, PFC on priority 3, andcma_roce_tos -t 106(DSCP 26/AF31) β skipping bond members and bond RDMA devices.
The Problem
GPU nodes with Mellanox ConnectX NICs need consistent RoCE QoS configuration across the fleet:
- DSCP trust mode so switches honor host markings instead of remarking to best-effort
- PFC on priority 3 for lossless RDMA traffic
- RoCE ToS 106 (DSCP 26 / AF31) so all RDMA traffic lands in the correct traffic class
MachineConfig can set sysctl values, but NIC-level configuration requires MOFED userspace tools (mlnx_qos, cma_roce_tos, ibdev2netdev). A DaemonSet with the DOCA driver image provides these tools and runs after the kernel driver is ready.
Key challenges:
- Must wait for MOFED driver to finish loading (race condition on boot)
- Must skip bond0 slave interfaces (bonding driver manages those)
- Must skip RDMA bond devices (
mlx5_bond_*) β only configure physical functions - Must only configure interfaces that are actually up
The Solution
DaemonSet Manifest
apiVersion: apps/v1
kind: DaemonSet
metadata:
name: mellanox-roce-dscp
namespace: nvidia-network-operator
spec:
selector:
matchLabels:
app: mellanox-roce-dscp
template:
metadata:
labels:
app: mellanox-roce-dscp
spec:
hostNetwork: true
hostPID: true
tolerations:
- operator: Exists
containers:
- name: roce-qos
image: nvcr.io/nvidia/mellanox/doca-driver:doca3.2.0-25.10-1.2.8.0-5.14.0-570.73.1.el9_6.x86_64-rhcos4.20-amd64
imagePullPolicy: IfNotPresent
securityContext:
privileged: true
command:
- /bin/bash
- -ceu
- |
set -euo pipefail
DRIVER_READY_FILE="/run/mellanox/drivers/.driver-ready"
WAIT_TIMEOUT=300
echo "[INFO] Waiting for Mellanox drivers: $DRIVER_READY_FILE"
# ββ Step 0: Wait for driver readiness ββ
SECONDS_WAITED=0
while [[ ! -f "$DRIVER_READY_FILE" ]]; do
if (( SECONDS_WAITED >= WAIT_TIMEOUT )); then
echo "[ERROR] Timeout waiting for Mellanox drivers"
exit 1
fi
sleep 2
((SECONDS_WAITED+=2))
done
echo "[INFO] Mellanox drivers are ready"
# ββ Step 1: Collect bond0 slave interfaces ββ
declare -A BOND0_SLAVES
if [[ -d /sys/class/net/bond0/bonding ]]; then
echo "[DEBUG] bond0 detected, collecting slaves"
for IFACE in $(< /sys/class/net/bond0/bonding/slaves); do
BOND0_SLAVES["$IFACE"]=1
done
fi
# ββ Step 2: Configure each Mellanox PF ββ
ibdev2netdev | while read -r IBDEV _ PORT _ NETDEV STATE; do
# Skip RDMA bond devices
if [[ "$IBDEV" == mlx5_bond_* ]]; then
echo "[DEBUG] Skipping RDMA bond device $IBDEV"
continue
fi
# Only configure Up interfaces
if [[ "$STATE" != "(Up)" ]]; then
continue
fi
IFACE="$NETDEV"
# Skip bond0 members
if [[ -n "${BOND0_SLAVES[$IFACE]:-}" ]]; then
echo "[INFO] Skipping $IFACE (bond0 slave)"
continue
fi
echo "[INFO] Configuring $IFACE (RDMA device $IBDEV)"
# Trust DSCP markings from the host
mlnx_qos -i "$IFACE" --trust dscp
# Enable PFC on priority 3 only
mlnx_qos -i "$IFACE" --pfc 0,0,0,1,0,0,0,0
# Set RoCE ToS = 106 (DSCP 26 = AF31)
echo 106 > /sys/class/infiniband/"$IBDEV"/tc/1/traffic_class
cma_roce_tos -d "$IBDEV" -t 106
done
echo "[INFO] RoCE DSCP QoS configuration completed"
tail -f /dev/null
volumeMounts:
- name: host-run
mountPath: /run
readOnly: true
volumes:
- name: host-run
hostPath:
path: /run
type: Directory
nodeSelector:
feature.node.kubernetes.io/pci-15b3.present: "true"How It Works
Driver Readiness Wait
The NVIDIA Network Operator (or MOFED DaemonSet) creates a sentinel file when drivers finish loading:
/run/mellanox/drivers/.driver-readyThe script polls for this file with a 300-second timeout. This prevents the race condition where mlnx_qos runs before the kernel module is loaded.
ibdev2netdev Parsing
ibdev2netdev outputs one line per RDMA port:
mlx5_0 port 1 ==> ens1f0 (Up)
mlx5_1 port 1 ==> ens1f1 (Up)
mlx5_bond_0 port 1 ==> bond0 (Up)The script parses each line into: IBDEV, port number, NETDEV, and STATE.
Bond Exclusion Logic
Two types of bonds are excluded:
RDMA bond devices (
mlx5_bond_*) β these are kernel-level RDMA aggregation devices managed by the bonding driver. Configuring them directly would conflict.bond0 slave interfaces β if
ens1f0andens1f1are bonded, configuring PFC on individual slaves can break the bondβs flow control negotiation. The bond driver manages QoS for its members.
graph TD
START[ibdev2netdev output] --> PARSE[Parse IBDEV, NETDEV, STATE]
PARSE --> Q1{IBDEV starts with<br/>mlx5_bond_?}
Q1 -->|Yes| SKIP1[Skip RDMA bond device]
Q1 -->|No| Q2{STATE == Up?}
Q2 -->|No| SKIP2[Skip down interface]
Q2 -->|Yes| Q3{NETDEV in<br/>bond0 slaves?}
Q3 -->|Yes| SKIP3[Skip bond member]
Q3 -->|No| CONFIGURE[Configure PF]
CONFIGURE --> TRUST[mlnx_qos --trust dscp]
TRUST --> PFC[mlnx_qos --pfc 0,0,0,1,0,0,0,0]
PFC --> TOS[echo 106 β traffic_class<br/>cma_roce_tos -t 106]
TOS --> DONE[Interface configured β
]ToS 106 Explained
The value 106 encodes both DSCP and ECN in the ToS byte:
ToS byte: 0 1 1 0 1 0 1 0
ββDSCPβββ βECNβ
DSCP = 011010 = 26 (decimal) = AF31
ECN = 10 = ECT(0) β ECN-Capable Transport
ToS = 01101010 = 106 (decimal) = 0x6A- DSCP 26 (AF31) maps to traffic class 3 on the switch β lossless queue
- ECN bits = 10 signals the NIC is ECN-capable β switches can mark instead of drop
cma_roce_tossets this for RDMA CM (Connection Manager) connections- Writing to
tc/1/traffic_classsets it for the RDMA traffic class
DOCA Driver Image
The image tag encodes the full driver and OS stack:
nvcr.io/nvidia/mellanox/doca-driver:doca3.2.0-25.10-1.2.8.0-5.14.0-570.73.1.el9_6.x86_64-rhcos4.20-amd64| Component | Value |
|---|---|
| DOCA version | 3.2.0 |
| MOFED version | 25.10-1.2.8.0 |
| Kernel | 5.14.0-570.73.1.el9_6 |
| OS | RHCOS 4.20 |
| Arch | amd64 |
β οΈ The image tag must match your nodeβs kernel and OS version exactly. Use
uname -ron a node to verify.
Node Selection
nodeSelector:
feature.node.kubernetes.io/pci-15b3.present: "true"NFD (Node Feature Discovery) automatically labels nodes with Mellanox PCI vendor ID 15b3. This ensures the DaemonSet only runs on nodes with Mellanox NICs.
Verification
# Check DaemonSet status
kubectl get ds mellanox-roce-dscp -n nvidia-network-operator
# Check logs on a specific node
kubectl logs -n nvidia-network-operator \
$(kubectl get pods -n nvidia-network-operator -l app=mellanox-roce-dscp \
--field-selector spec.nodeName=gpu-worker-0 -o name) | head -20
# Expected output:
# [INFO] Mellanox drivers are ready
# [DEBUG] bond0 detected, collecting slaves
# [INFO] Skipping ens1f0np0 (bond0 slave)
# [INFO] Configuring ens2f0np0 (RDMA device mlx5_2)
# [INFO] RoCE DSCP QoS configuration completed
# Verify on node
oc debug node/gpu-worker-0 -- chroot /host mlnx_qos -i ens2f0np0
# trust state: dscp
# PFC: 0,0,0,1,0,0,0,0
# Verify ToS
oc debug node/gpu-worker-0 -- chroot /host \
cat /sys/class/infiniband/mlx5_2/tc/1/traffic_class
# 106Common Issues
DaemonSet pod stuck in CrashLoopBackOff β driver readiness timeout
The MOFED driver DaemonSet hasnβt created /run/mellanox/drivers/.driver-ready within 300 seconds. Check:
kubectl get ds -n nvidia-network-operator | grep mofed
kubectl logs -n nvidia-network-operator <mofed-pod>Image pull fails β wrong kernel version in tag
The DOCA driver image tag must match the node kernel exactly:
oc debug node/gpu-worker-0 -- uname -r
# 5.14.0-570.73.1.el9_6.x86_64If the kernel was updated, you need a new DOCA driver image tag.
mlnx_qos reports βOperation not supportedβ on VFs
This DaemonSet only configures PFs (physical functions). VF QoS is inherited from the PF or configured via SR-IOV Network Operator policies. The bond exclusion logic already filters out non-PF devices.
PFC counters incrementing rapidly after configuration
PFC is working correctly β itβs preventing drops. If counters grow too fast, add ECN (not configured by this DaemonSet β use the ECN MachineConfig recipe) to reduce PFC activation.
bond0 slaves getting configured despite exclusion
Check that /sys/class/net/bond0/bonding/slaves is readable. The DaemonSet mounts /run read-only β bond info is under /sys which is always available in hostNetwork + hostPID mode.
Best Practices
- Pin the DOCA driver image to your exact kernel β mismatched images cause module load failures
- Use
tail -f /dev/nullto keep the container running after configuration β allows log inspection andkubectl execfor debugging - Node Feature Discovery label (
pci-15b3.present) is more reliable than manual node labels - Mount
/runread-only β only needs to read the driver-ready sentinel, not write anything - Run in
nvidia-network-operatornamespace β collocates with MOFED and Network Operator pods - Add ECN configuration alongside PFC for a complete lossless stack (see related ECN MachineConfig recipe)
- Tolerate all taints (
operator: Exists) β GPU nodes often have taints to prevent non-GPU workloads - Log verbosity: Uncomment
set -xfor full bash trace during debugging, re-comment for production
Key Takeaways
- The DaemonSet pattern gives you MOFED tools (
mlnx_qos,cma_roce_tos,ibdev2netdev) without installing RPMs on nodes - Wait for
/run/mellanox/drivers/.driver-readybefore running any Mellanox CLI tools ibdev2netdevis the single source of truth for RDMA device β network interface mapping- Skip bond devices (both
mlx5_bond_*RDMA devices and bond0 slave interfaces) - ToS 106 = DSCP 26 (AF31) + ECN ECT(0) β the standard RoCEv2 marking
cma_roce_tossets ToS for RDMA CM connections;traffic_classsysfs sets it for the RDMA TC- DOCA driver image tag must match node kernel version exactly
- This DaemonSet handles PF configuration; VF QoS comes from SR-IOV Network Operator

Recommended
Kubernetes Recipes β The Complete Book100+ production-ready patterns with detailed explanations, best practices, and copy-paste YAML. Everything in one place.
Get the Book βLearn by Doing
CopyPasteLearn β Hands-on Cloud & DevOps CoursesMaster Kubernetes, Ansible, Terraform, and MLOps with interactive, copy-paste-run lessons. Start free.
Browse Courses βπ Deepen Your Skills β Hands-on Courses
Courses by CopyPasteLearn.com β Learn IT by Doing