Networking advanced ⏱ 20 minutes K8s 1.28+

mlnx_qos QoS on MOFED Containers

Configure RDMA QoS with mlnx_qos from MOFED containers on Kubernetes. Set PFC, ETS, DSCP trust mode, and validate lossless RoCE traffic classes on ConnectX.

By Luca Berton β€’ β€’ πŸ“– 9 min read

πŸ’‘ Quick Answer: mlnx_qos -i eth0 shows PFC, ETS, and DSCP trust configuration on Mellanox/NVIDIA ConnectX NICs. Run it from a MOFED (Mellanox OFED) privileged container DaemonSet with hostNetwork: true and access to /dev/mst devices.

The Problem

Lossless RoCE for GPU training requires precise QoS configuration on every NIC:

  • PFC (Priority Flow Control) must be enabled on the right traffic class (typically priority 3)
  • ETS (Enhanced Transmission Selection) must allocate bandwidth correctly
  • DSCP trust mode must be set so the NIC honors application-marked packets
  • You need to verify and configure these settings across hundreds of nodes

The mlnx_qos tool is part of Mellanox OFED and doesn’t ship in standard container images. Running it at scale requires a MOFED container with host-level access.

The Solution

Quick Reference: mlnx_qos Output

mlnx_qos -i eth0

Output breakdown:

Priority trust state: dscp

PFC configuration:
        priority    0   1   2   3   4   5   6   7
        enabled     0   0   0   1   0   0   0   0
        buffer      0   0   0   1   0   0   0   0

tc: 0 ratelimit: unlimited, tsa: ets, bw: 0%
tc: 1 ratelimit: unlimited, tsa: ets, bw: 0%
tc: 2 ratelimit: unlimited, tsa: ets, bw: 0%
tc: 3 ratelimit: unlimited, tsa: ets, bw: 100%
tc: 4 ratelimit: unlimited, tsa: ets, bw: 0%
tc: 5 ratelimit: unlimited, tsa: ets, bw: 0%
tc: 6 ratelimit: unlimited, tsa: ets, bw: 0%
tc: 7 ratelimit: unlimited, tsa: ets, bw: 0%
FieldExpected for RoCEWhy
Trust statedscpNIC uses DSCP field (not 802.1p VLAN PCP) to classify traffic
PFC priority 3enabled: 1RoCEv2 default maps DSCP 26 (AF31) β†’ priority 3
PFC other prioritiesenabled: 0Only lossless on RDMA priority; lossy for everything else
TC 3 bandwidth100% (or dominant share)Ensure RDMA traffic gets the bandwidth it needs
TSAetsEnhanced Transmission Selection (IEEE 802.1Qaz)

MOFED Container DaemonSet

Deploy a MOFED tools container across all GPU/RDMA nodes:

apiVersion: apps/v1
kind: DaemonSet
metadata:
  name: mofed-tools
  namespace: nvidia-network-operator
spec:
  selector:
    matchLabels:
      app: mofed-tools
  template:
    metadata:
      labels:
        app: mofed-tools
    spec:
      nodeSelector:
        feature.node.kubernetes.io/network-sriov.capable: "true"
      hostNetwork: true
      hostPID: true
      containers:
        - name: mofed
          image: nvcr.io/nvidia/mellanox/mofed-container:24.07-0.7.0.0
          securityContext:
            privileged: true
          command:
            - sleep
            - infinity
          volumeMounts:
            - name: dev
              mountPath: /dev
            - name: sys
              mountPath: /sys
            - name: host-etc
              mountPath: /host/etc
              readOnly: true
          resources:
            requests:
              cpu: 100m
              memory: 256Mi
            limits:
              cpu: 500m
              memory: 512Mi
      volumes:
        - name: dev
          hostPath:
            path: /dev
        - name: sys
          hostPath:
            path: /sys
        - name: host-etc
          hostPath:
            path: /etc

Query QoS on All Nodes

# List MOFED pods
kubectl get pods -n nvidia-network-operator -l app=mofed-tools -o wide

# Check QoS on a specific node
kubectl exec -n nvidia-network-operator mofed-tools-abc12 -- mlnx_qos -i eth0

# Check all RDMA interfaces
kubectl exec -n nvidia-network-operator mofed-tools-abc12 -- bash -c '
for iface in $(ls /sys/class/infiniband/*/device/net/ 2>/dev/null); do
  echo "=== $iface ==="
  mlnx_qos -i $iface
  echo
done'

# Fleet-wide check (all nodes)
for pod in $(kubectl get pods -n nvidia-network-operator -l app=mofed-tools -o name); do
  node=$(kubectl get $pod -n nvidia-network-operator -o jsonpath='{.spec.nodeName}')
  echo "=== Node: $node ==="
  kubectl exec -n nvidia-network-operator ${pod##*/} -- mlnx_qos -i ens8f0 2>&1 | head -20
  echo
done

Configure QoS from MOFED Container

# Set DSCP trust mode (required for RoCEv2)
kubectl exec -n nvidia-network-operator mofed-tools-abc12 -- \
  mlnx_qos -i eth0 --trust dscp

# Enable PFC on priority 3 only
kubectl exec -n nvidia-network-operator mofed-tools-abc12 -- \
  mlnx_qos -i eth0 --pfc 0,0,0,1,0,0,0,0

# Configure ETS: 100% bandwidth to TC 3
kubectl exec -n nvidia-network-operator mofed-tools-abc12 -- \
  mlnx_qos -i eth0 --tc_bw 0,0,0,100,0,0,0,0

# All in one command
kubectl exec -n nvidia-network-operator mofed-tools-abc12 -- \
  mlnx_qos -i eth0 --trust dscp --pfc 0,0,0,1,0,0,0,0 --tc_bw 0,0,0,100,0,0,0,0

Fleet-Wide Configuration DaemonSet

For production, configure QoS at boot via an init container or startup script:

apiVersion: apps/v1
kind: DaemonSet
metadata:
  name: roce-qos-config
  namespace: nvidia-network-operator
spec:
  selector:
    matchLabels:
      app: roce-qos-config
  template:
    metadata:
      labels:
        app: roce-qos-config
    spec:
      nodeSelector:
        feature.node.kubernetes.io/network-sriov.capable: "true"
      hostNetwork: true
      initContainers:
        - name: configure-qos
          image: nvcr.io/nvidia/mellanox/mofed-container:24.07-0.7.0.0
          securityContext:
            privileged: true
          command:
            - bash
            - -c
            - |
              # Configure all Mellanox interfaces
              for iface in $(ls /sys/class/infiniband/*/device/net/ 2>/dev/null); do
                echo "Configuring QoS on $iface"
                mlnx_qos -i $iface --trust dscp --pfc 0,0,0,1,0,0,0,0 --tc_bw 0,0,0,100,0,0,0,0
                echo "Verifying $iface:"
                mlnx_qos -i $iface
                echo "---"
              done
          volumeMounts:
            - name: dev
              mountPath: /dev
            - name: sys
              mountPath: /sys
      containers:
        - name: monitor
          image: nvcr.io/nvidia/mellanox/mofed-container:24.07-0.7.0.0
          securityContext:
            privileged: true
          command:
            - bash
            - -c
            - |
              while true; do
                for iface in $(ls /sys/class/infiniband/*/device/net/ 2>/dev/null); do
                  trust=$(mlnx_qos -i $iface 2>/dev/null | grep "trust state" | awk '{print $NF}')
                  pfc3=$(mlnx_qos -i $iface 2>/dev/null | grep -A1 "enabled" | tail -1 | awk '{print $4}')
                  if [ "$trust" != "dscp" ] || [ "$pfc3" != "1" ]; then
                    echo "WARNING: $iface QoS drift detected! trust=$trust pfc3=$pfc3"
                    echo "Re-applying QoS configuration..."
                    mlnx_qos -i $iface --trust dscp --pfc 0,0,0,1,0,0,0,0 --tc_bw 0,0,0,100,0,0,0,0
                  fi
                done
                sleep 300
              done
          volumeMounts:
            - name: dev
              mountPath: /dev
            - name: sys
              mountPath: /sys
      volumes:
        - name: dev
          hostPath:
            path: /dev
        - name: sys
          hostPath:
            path: /sys

OpenShift MachineConfig Alternative

On OpenShift, you can set QoS via a systemd unit in MachineConfig:

apiVersion: machineconfiguration.openshift.io/v1
kind: MachineConfig
metadata:
  name: 99-worker-roce-qos
  labels:
    machineconfiguration.openshift.io/role: worker
spec:
  config:
    ignition:
      version: 3.2.0
    systemd:
      units:
        - name: roce-qos.service
          enabled: true
          contents: |
            [Unit]
            Description=Configure RoCE QoS on Mellanox NICs
            After=network-online.target openibd.service
            Wants=network-online.target

            [Service]
            Type=oneshot
            RemainAfterExit=yes
            ExecStart=/bin/bash -c 'for iface in $(ls /sys/class/infiniband/*/device/net/ 2>/dev/null); do mlnx_qos -i $iface --trust dscp --pfc 0,0,0,1,0,0,0,0 --tc_bw 0,0,0,100,0,0,0,0; done'

            [Install]
            WantedBy=multi-user.target

mlnx_qos Command Reference

# Show current configuration
mlnx_qos -i eth0

# Set DSCP trust (vs pcp for VLAN priority)
mlnx_qos -i eth0 --trust dscp

# Set PFC per priority (8 values: pri0,pri1,...,pri7)
mlnx_qos -i eth0 --pfc 0,0,0,1,0,0,0,0

# Set ETS bandwidth allocation per TC (must sum to 100)
mlnx_qos -i eth0 --tc_bw 10,0,0,90,0,0,0,0

# Set TSA type per TC (ets, strict, vendor)
mlnx_qos -i eth0 --tsa ets,ets,ets,ets,ets,ets,ets,ets

# Set rate limit per TC (in Gbps, 0 = unlimited)
mlnx_qos -i eth0 --ratelimit 0,0,0,0,0,0,0,0

# Set DSCP-to-priority mapping
mlnx_qos -i eth0 --dscp2prio set,26,3
# DSCP 26 (AF31) β†’ priority 3

# Show cable info (bonus)
mlnx_qos -i eth0 --cable
graph TD
    subgraph MOFED Container DaemonSet
        MC[mofed-container<br/>privileged: true<br/>hostNetwork: true]
        MC -->|mlnx_qos -i| NIC1[ens8f0<br/>ConnectX-7]
        MC -->|mlnx_qos -i| NIC2[ens8f1<br/>ConnectX-7]
    end
    
    subgraph QoS Configuration
        NIC1 --> DSCP[Trust: DSCP]
        NIC1 --> PFC[PFC: Priority 3 ON]
        NIC1 --> ETS[ETS: TC3 = 100%]
    end
    
    subgraph Traffic Flow
        GPU[GPU Pod<br/>NCCL DSCP 26] -->|RoCEv2| NIC1
        NIC1 -->|Priority 3<br/>Lossless| SW[Switch<br/>PFC enabled]
        SW -->|Priority 3<br/>Lossless| RNIC[Remote NIC]
    end

Common Issues

mlnx_qos: command not found

The tool is part of Mellanox OFED. Use the official MOFED container:

# Check if mlnx_qos exists
kubectl exec mofed-tools-abc12 -- which mlnx_qos
# /usr/bin/mlnx_qos (from mlnx-tools package)

On bare metal, install via: apt install mlnx-tools or yum install mlnx-tools.

mlnx_qos: No such device or permission error

The container needs privileged: true and hostNetwork: true to access host NICs:

securityContext:
  privileged: true
hostNetwork: true

Also mount /dev and /sys from the host.

Trust mode resets after reboot

mlnx_qos settings are not persistent by default. Use one of:

  1. DaemonSet init container (re-applies on pod restart)
  2. MachineConfig systemd unit (OpenShift β€” runs at boot)
  3. NMState NNCP with ieee-802-1-Qaz (declarative, reconciled by operator)

PFC enabled but still seeing drops

Both ends (NIC + switch port) must have PFC enabled on the same priority:

# Check PFC counters
ethtool -S eth0 | grep prio3
# rx_prio3_pause  β€” PFC frames received (switch is congested)
# tx_prio3_pause  β€” PFC frames sent (NIC buffer filling up)
# rx_prio3_discard β€” Drops DESPITE PFC (configuration mismatch)

If rx_prio3_discard is incrementing, the switch isn’t honoring PFC β€” check switch-side config.

ETS bandwidth percentages must sum to 100

# Wrong: doesn't sum to 100
mlnx_qos -i eth0 --tc_bw 0,0,0,50,0,0,0,0
# Error or unexpected behavior

# Correct: allocate remaining to TC 0
mlnx_qos -i eth0 --tc_bw 10,0,0,90,0,0,0,0

Different interface names across nodes

Interface names vary by hardware and OS. Discover dynamically:

# Find all Mellanox interfaces
ls /sys/class/infiniband/*/device/net/

# Or by PCI vendor
for dev in /sys/class/net/*/device/vendor; do
  [ "$(cat $dev 2>/dev/null)" = "0x15b3" ] && basename $(dirname $(dirname $dev))
done

Best Practices

  • Deploy MOFED tools as a DaemonSet with privileged: true β€” always available for debugging
  • Use init containers for fleet-wide QoS configuration at pod startup
  • Add a monitoring loop to detect and correct QoS drift (firmware updates, driver reloads)
  • Only enable PFC on the RDMA priority (3) β€” enabling on all priorities risks deadlocks
  • Allocate dominant ETS bandwidth to the RDMA TC (80-100%)
  • Set --trust dscp for RoCEv2 β€” PCP trust only works with VLAN-tagged traffic
  • Map DSCP 26 (AF31) to priority 3 β€” this is the RoCEv2 default and matches switch expectations
  • Verify both NIC and switch have matching PFC configuration β€” mismatched PFC causes drops
  • Use ethtool -S PFC counters to monitor real-time flow control activity
  • On OpenShift, prefer MachineConfig + systemd for persistence over DaemonSet (survives pod eviction)

Key Takeaways

  • mlnx_qos -i <iface> shows PFC, ETS, trust mode, and TC bandwidth in one command
  • MOFED container (nvcr.io/nvidia/mellanox/mofed-container) provides mlnx_qos and all Mellanox tools
  • Container needs privileged: true + hostNetwork: true + /dev + /sys mounts
  • Settings are volatile β€” persist via DaemonSet init container, MachineConfig systemd, or NMState NNCP
  • PFC priority 3 + DSCP trust + DSCP 26β†’priority 3 mapping = standard lossless RoCE config
  • ETS bandwidth percentages across all TCs must sum to 100
  • Monitor PFC counters (ethtool -S) to verify lossless behavior on the wire
  • Switch-side PFC must match NIC-side β€” both ends must agree on which priority is lossless
#mlnx-qos #mofed #pfc #ets #roce #dscp #qos
Luca Berton
Written by Luca Berton

Principal Solutions Architect specializing in Kubernetes, AI/GPU infrastructure, and cloud-native platforms. Author of Kubernetes Recipes and creator of CopyPasteLearn courses.

Kubernetes Recipes book cover

Want More Kubernetes Recipes?

This recipe is from Kubernetes Recipes, our 750-page practical guide with hundreds of production-ready patterns.

Luca Berton Ansible Pilot Ansible by Example Open Empower K8s Recipes Terraform Pilot CopyPasteLearn ProteinLens