mlnx_qos QoS on MOFED Containers
Configure RDMA QoS with mlnx_qos from MOFED containers on Kubernetes. Set PFC, ETS, DSCP trust mode, and validate lossless RoCE traffic classes on ConnectX.
π‘ Quick Answer:
mlnx_qos -i eth0shows PFC, ETS, and DSCP trust configuration on Mellanox/NVIDIA ConnectX NICs. Run it from a MOFED (Mellanox OFED) privileged container DaemonSet withhostNetwork: trueand access to/dev/mstdevices.
The Problem
Lossless RoCE for GPU training requires precise QoS configuration on every NIC:
- PFC (Priority Flow Control) must be enabled on the right traffic class (typically priority 3)
- ETS (Enhanced Transmission Selection) must allocate bandwidth correctly
- DSCP trust mode must be set so the NIC honors application-marked packets
- You need to verify and configure these settings across hundreds of nodes
The mlnx_qos tool is part of Mellanox OFED and doesnβt ship in standard container images. Running it at scale requires a MOFED container with host-level access.
The Solution
Quick Reference: mlnx_qos Output
mlnx_qos -i eth0Output breakdown:
Priority trust state: dscp
PFC configuration:
priority 0 1 2 3 4 5 6 7
enabled 0 0 0 1 0 0 0 0
buffer 0 0 0 1 0 0 0 0
tc: 0 ratelimit: unlimited, tsa: ets, bw: 0%
tc: 1 ratelimit: unlimited, tsa: ets, bw: 0%
tc: 2 ratelimit: unlimited, tsa: ets, bw: 0%
tc: 3 ratelimit: unlimited, tsa: ets, bw: 100%
tc: 4 ratelimit: unlimited, tsa: ets, bw: 0%
tc: 5 ratelimit: unlimited, tsa: ets, bw: 0%
tc: 6 ratelimit: unlimited, tsa: ets, bw: 0%
tc: 7 ratelimit: unlimited, tsa: ets, bw: 0%| Field | Expected for RoCE | Why |
|---|---|---|
| Trust state | dscp | NIC uses DSCP field (not 802.1p VLAN PCP) to classify traffic |
| PFC priority 3 | enabled: 1 | RoCEv2 default maps DSCP 26 (AF31) β priority 3 |
| PFC other priorities | enabled: 0 | Only lossless on RDMA priority; lossy for everything else |
| TC 3 bandwidth | 100% (or dominant share) | Ensure RDMA traffic gets the bandwidth it needs |
| TSA | ets | Enhanced Transmission Selection (IEEE 802.1Qaz) |
MOFED Container DaemonSet
Deploy a MOFED tools container across all GPU/RDMA nodes:
apiVersion: apps/v1
kind: DaemonSet
metadata:
name: mofed-tools
namespace: nvidia-network-operator
spec:
selector:
matchLabels:
app: mofed-tools
template:
metadata:
labels:
app: mofed-tools
spec:
nodeSelector:
feature.node.kubernetes.io/network-sriov.capable: "true"
hostNetwork: true
hostPID: true
containers:
- name: mofed
image: nvcr.io/nvidia/mellanox/mofed-container:24.07-0.7.0.0
securityContext:
privileged: true
command:
- sleep
- infinity
volumeMounts:
- name: dev
mountPath: /dev
- name: sys
mountPath: /sys
- name: host-etc
mountPath: /host/etc
readOnly: true
resources:
requests:
cpu: 100m
memory: 256Mi
limits:
cpu: 500m
memory: 512Mi
volumes:
- name: dev
hostPath:
path: /dev
- name: sys
hostPath:
path: /sys
- name: host-etc
hostPath:
path: /etcQuery QoS on All Nodes
# List MOFED pods
kubectl get pods -n nvidia-network-operator -l app=mofed-tools -o wide
# Check QoS on a specific node
kubectl exec -n nvidia-network-operator mofed-tools-abc12 -- mlnx_qos -i eth0
# Check all RDMA interfaces
kubectl exec -n nvidia-network-operator mofed-tools-abc12 -- bash -c '
for iface in $(ls /sys/class/infiniband/*/device/net/ 2>/dev/null); do
echo "=== $iface ==="
mlnx_qos -i $iface
echo
done'
# Fleet-wide check (all nodes)
for pod in $(kubectl get pods -n nvidia-network-operator -l app=mofed-tools -o name); do
node=$(kubectl get $pod -n nvidia-network-operator -o jsonpath='{.spec.nodeName}')
echo "=== Node: $node ==="
kubectl exec -n nvidia-network-operator ${pod##*/} -- mlnx_qos -i ens8f0 2>&1 | head -20
echo
doneConfigure QoS from MOFED Container
# Set DSCP trust mode (required for RoCEv2)
kubectl exec -n nvidia-network-operator mofed-tools-abc12 -- \
mlnx_qos -i eth0 --trust dscp
# Enable PFC on priority 3 only
kubectl exec -n nvidia-network-operator mofed-tools-abc12 -- \
mlnx_qos -i eth0 --pfc 0,0,0,1,0,0,0,0
# Configure ETS: 100% bandwidth to TC 3
kubectl exec -n nvidia-network-operator mofed-tools-abc12 -- \
mlnx_qos -i eth0 --tc_bw 0,0,0,100,0,0,0,0
# All in one command
kubectl exec -n nvidia-network-operator mofed-tools-abc12 -- \
mlnx_qos -i eth0 --trust dscp --pfc 0,0,0,1,0,0,0,0 --tc_bw 0,0,0,100,0,0,0,0Fleet-Wide Configuration DaemonSet
For production, configure QoS at boot via an init container or startup script:
apiVersion: apps/v1
kind: DaemonSet
metadata:
name: roce-qos-config
namespace: nvidia-network-operator
spec:
selector:
matchLabels:
app: roce-qos-config
template:
metadata:
labels:
app: roce-qos-config
spec:
nodeSelector:
feature.node.kubernetes.io/network-sriov.capable: "true"
hostNetwork: true
initContainers:
- name: configure-qos
image: nvcr.io/nvidia/mellanox/mofed-container:24.07-0.7.0.0
securityContext:
privileged: true
command:
- bash
- -c
- |
# Configure all Mellanox interfaces
for iface in $(ls /sys/class/infiniband/*/device/net/ 2>/dev/null); do
echo "Configuring QoS on $iface"
mlnx_qos -i $iface --trust dscp --pfc 0,0,0,1,0,0,0,0 --tc_bw 0,0,0,100,0,0,0,0
echo "Verifying $iface:"
mlnx_qos -i $iface
echo "---"
done
volumeMounts:
- name: dev
mountPath: /dev
- name: sys
mountPath: /sys
containers:
- name: monitor
image: nvcr.io/nvidia/mellanox/mofed-container:24.07-0.7.0.0
securityContext:
privileged: true
command:
- bash
- -c
- |
while true; do
for iface in $(ls /sys/class/infiniband/*/device/net/ 2>/dev/null); do
trust=$(mlnx_qos -i $iface 2>/dev/null | grep "trust state" | awk '{print $NF}')
pfc3=$(mlnx_qos -i $iface 2>/dev/null | grep -A1 "enabled" | tail -1 | awk '{print $4}')
if [ "$trust" != "dscp" ] || [ "$pfc3" != "1" ]; then
echo "WARNING: $iface QoS drift detected! trust=$trust pfc3=$pfc3"
echo "Re-applying QoS configuration..."
mlnx_qos -i $iface --trust dscp --pfc 0,0,0,1,0,0,0,0 --tc_bw 0,0,0,100,0,0,0,0
fi
done
sleep 300
done
volumeMounts:
- name: dev
mountPath: /dev
- name: sys
mountPath: /sys
volumes:
- name: dev
hostPath:
path: /dev
- name: sys
hostPath:
path: /sysOpenShift MachineConfig Alternative
On OpenShift, you can set QoS via a systemd unit in MachineConfig:
apiVersion: machineconfiguration.openshift.io/v1
kind: MachineConfig
metadata:
name: 99-worker-roce-qos
labels:
machineconfiguration.openshift.io/role: worker
spec:
config:
ignition:
version: 3.2.0
systemd:
units:
- name: roce-qos.service
enabled: true
contents: |
[Unit]
Description=Configure RoCE QoS on Mellanox NICs
After=network-online.target openibd.service
Wants=network-online.target
[Service]
Type=oneshot
RemainAfterExit=yes
ExecStart=/bin/bash -c 'for iface in $(ls /sys/class/infiniband/*/device/net/ 2>/dev/null); do mlnx_qos -i $iface --trust dscp --pfc 0,0,0,1,0,0,0,0 --tc_bw 0,0,0,100,0,0,0,0; done'
[Install]
WantedBy=multi-user.targetmlnx_qos Command Reference
# Show current configuration
mlnx_qos -i eth0
# Set DSCP trust (vs pcp for VLAN priority)
mlnx_qos -i eth0 --trust dscp
# Set PFC per priority (8 values: pri0,pri1,...,pri7)
mlnx_qos -i eth0 --pfc 0,0,0,1,0,0,0,0
# Set ETS bandwidth allocation per TC (must sum to 100)
mlnx_qos -i eth0 --tc_bw 10,0,0,90,0,0,0,0
# Set TSA type per TC (ets, strict, vendor)
mlnx_qos -i eth0 --tsa ets,ets,ets,ets,ets,ets,ets,ets
# Set rate limit per TC (in Gbps, 0 = unlimited)
mlnx_qos -i eth0 --ratelimit 0,0,0,0,0,0,0,0
# Set DSCP-to-priority mapping
mlnx_qos -i eth0 --dscp2prio set,26,3
# DSCP 26 (AF31) β priority 3
# Show cable info (bonus)
mlnx_qos -i eth0 --cablegraph TD
subgraph MOFED Container DaemonSet
MC[mofed-container<br/>privileged: true<br/>hostNetwork: true]
MC -->|mlnx_qos -i| NIC1[ens8f0<br/>ConnectX-7]
MC -->|mlnx_qos -i| NIC2[ens8f1<br/>ConnectX-7]
end
subgraph QoS Configuration
NIC1 --> DSCP[Trust: DSCP]
NIC1 --> PFC[PFC: Priority 3 ON]
NIC1 --> ETS[ETS: TC3 = 100%]
end
subgraph Traffic Flow
GPU[GPU Pod<br/>NCCL DSCP 26] -->|RoCEv2| NIC1
NIC1 -->|Priority 3<br/>Lossless| SW[Switch<br/>PFC enabled]
SW -->|Priority 3<br/>Lossless| RNIC[Remote NIC]
endCommon Issues
mlnx_qos: command not found
The tool is part of Mellanox OFED. Use the official MOFED container:
# Check if mlnx_qos exists
kubectl exec mofed-tools-abc12 -- which mlnx_qos
# /usr/bin/mlnx_qos (from mlnx-tools package)On bare metal, install via: apt install mlnx-tools or yum install mlnx-tools.
mlnx_qos: No such device or permission error
The container needs privileged: true and hostNetwork: true to access host NICs:
securityContext:
privileged: true
hostNetwork: trueAlso mount /dev and /sys from the host.
Trust mode resets after reboot
mlnx_qos settings are not persistent by default. Use one of:
- DaemonSet init container (re-applies on pod restart)
- MachineConfig systemd unit (OpenShift β runs at boot)
- NMState NNCP with
ieee-802-1-Qaz(declarative, reconciled by operator)
PFC enabled but still seeing drops
Both ends (NIC + switch port) must have PFC enabled on the same priority:
# Check PFC counters
ethtool -S eth0 | grep prio3
# rx_prio3_pause β PFC frames received (switch is congested)
# tx_prio3_pause β PFC frames sent (NIC buffer filling up)
# rx_prio3_discard β Drops DESPITE PFC (configuration mismatch)If rx_prio3_discard is incrementing, the switch isnβt honoring PFC β check switch-side config.
ETS bandwidth percentages must sum to 100
# Wrong: doesn't sum to 100
mlnx_qos -i eth0 --tc_bw 0,0,0,50,0,0,0,0
# Error or unexpected behavior
# Correct: allocate remaining to TC 0
mlnx_qos -i eth0 --tc_bw 10,0,0,90,0,0,0,0Different interface names across nodes
Interface names vary by hardware and OS. Discover dynamically:
# Find all Mellanox interfaces
ls /sys/class/infiniband/*/device/net/
# Or by PCI vendor
for dev in /sys/class/net/*/device/vendor; do
[ "$(cat $dev 2>/dev/null)" = "0x15b3" ] && basename $(dirname $(dirname $dev))
doneBest Practices
- Deploy MOFED tools as a DaemonSet with
privileged: trueβ always available for debugging - Use init containers for fleet-wide QoS configuration at pod startup
- Add a monitoring loop to detect and correct QoS drift (firmware updates, driver reloads)
- Only enable PFC on the RDMA priority (3) β enabling on all priorities risks deadlocks
- Allocate dominant ETS bandwidth to the RDMA TC (80-100%)
- Set
--trust dscpfor RoCEv2 β PCP trust only works with VLAN-tagged traffic - Map DSCP 26 (AF31) to priority 3 β this is the RoCEv2 default and matches switch expectations
- Verify both NIC and switch have matching PFC configuration β mismatched PFC causes drops
- Use
ethtool -SPFC counters to monitor real-time flow control activity - On OpenShift, prefer MachineConfig + systemd for persistence over DaemonSet (survives pod eviction)
Key Takeaways
mlnx_qos -i <iface>shows PFC, ETS, trust mode, and TC bandwidth in one command- MOFED container (
nvcr.io/nvidia/mellanox/mofed-container) providesmlnx_qosand all Mellanox tools - Container needs
privileged: true+hostNetwork: true+/dev+/sysmounts - Settings are volatile β persist via DaemonSet init container, MachineConfig systemd, or NMState NNCP
- PFC priority 3 + DSCP trust + DSCP 26βpriority 3 mapping = standard lossless RoCE config
- ETS bandwidth percentages across all TCs must sum to 100
- Monitor PFC counters (
ethtool -S) to verify lossless behavior on the wire - Switch-side PFC must match NIC-side β both ends must agree on which priority is lossless

Recommended
Kubernetes Recipes β The Complete Book100+ production-ready patterns with detailed explanations, best practices, and copy-paste YAML. Everything in one place.
Get the Book βLearn by Doing
CopyPasteLearn β Hands-on Cloud & DevOps CoursesMaster Kubernetes, Ansible, Terraform, and MLOps with interactive, copy-paste-run lessons. Start free.
Browse Courses βπ Deepen Your Skills β Hands-on Courses
Courses by CopyPasteLearn.com β Learn IT by Doing