NNCP Multi-NIC Architecture for Workers
Design a complete multi-NIC worker node architecture with NNCP for separated management, storage, tenant, and GPU traffic using bonds, VLANs, and bridges.
π‘ Quick Answer: Use separate bonded interfaces for each traffic class β management (bond0), storage (bond1), tenant/VM (bond2), and GPU/RDMA (bond3). Layer VLANs on bonds for sub-segmentation and Linux bridges on top for KubeVirt VM access.
The Problem
Production Kubernetes worker nodes handle multiple types of traffic that must be separated for performance, security, and reliability:
- Management/API β kubelet, kube-proxy, API server communication
- Storage β Ceph OSD replication, NFS mounts, iSCSI targets
- Tenant/VM β KubeVirt VM external networking, multi-tenant isolation
- GPU/RDMA β distributed AI training, inter-node tensor transfers
Mixing all traffic on a single NIC creates contention β a large Ceph rebalance can starve GPU training traffic. Proper multi-NIC architecture with NNCP provides declarative, reproducible network configuration across the fleet.
The Solution
Complete Multi-NIC Architecture
A typical 4-bond production worker node:
apiVersion: nmstate.io/v1
kind: NodeNetworkConfigurationPolicy
metadata:
name: worker-0-multi-nic
spec:
nodeSelector:
kubernetes.io/hostname: worker-0
maxUnavailable: 1
desiredState:
interfaces:
# ==========================================
# Bond 0: Management (ens192 + ens193)
# ==========================================
- name: ens192
type: ethernet
state: up
ipv4:
enabled: false
ipv6:
enabled: false
- name: ens193
type: ethernet
state: up
ipv4:
enabled: false
ipv6:
enabled: false
- name: bond0
type: bond
state: up
ipv4:
enabled: true
dhcp: false
address:
- ip: 10.0.1.10
prefix-length: 24
ipv6:
enabled: false
link-aggregation:
mode: active-backup
options:
miimon: "100"
primary: ens192
port:
- ens192
- ens193
# ==========================================
# Bond 1: Storage (ens224 + ens225) MTU 9000
# ==========================================
- name: ens224
type: ethernet
state: up
mtu: 9000
ipv4:
enabled: false
ipv6:
enabled: false
- name: ens225
type: ethernet
state: up
mtu: 9000
ipv4:
enabled: false
ipv6:
enabled: false
- name: bond1
type: bond
state: up
mtu: 9000
ipv4:
enabled: false
ipv6:
enabled: false
link-aggregation:
mode: 802.3ad
options:
miimon: "100"
lacp_rate: "fast"
xmit_hash_policy: "layer3+4"
port:
- ens224
- ens225
# Storage VLANs on bond1
- name: bond1.100
type: vlan
state: up
mtu: 9000
vlan:
base-iface: bond1
id: 100
ipv4:
enabled: true
dhcp: false
address:
- ip: 10.100.0.10
prefix-length: 24
- name: bond1.101
type: vlan
state: up
mtu: 9000
vlan:
base-iface: bond1
id: 101
ipv4:
enabled: true
dhcp: false
address:
- ip: 10.101.0.10
prefix-length: 24
# ==========================================
# Bond 2: Tenant and VM (ens256 + ens257)
# ==========================================
- name: ens256
type: ethernet
state: up
ipv4:
enabled: false
ipv6:
enabled: false
- name: ens257
type: ethernet
state: up
ipv4:
enabled: false
ipv6:
enabled: false
- name: bond2
type: bond
state: up
ipv4:
enabled: false
ipv6:
enabled: false
link-aggregation:
mode: 802.3ad
options:
miimon: "100"
port:
- ens256
- ens257
# Tenant VLANs with bridges for KubeVirt
- name: bond2.200
type: vlan
state: up
vlan:
base-iface: bond2
id: 200
ipv4:
enabled: false
- name: br-tenant-a
type: linux-bridge
state: up
ipv4:
enabled: false
ipv6:
enabled: false
bridge:
options:
stp:
enabled: false
port:
- name: bond2.200
- name: bond2.201
type: vlan
state: up
vlan:
base-iface: bond2
id: 201
ipv4:
enabled: false
- name: br-tenant-b
type: linux-bridge
state: up
ipv4:
enabled: false
ipv6:
enabled: false
bridge:
options:
stp:
enabled: false
port:
- name: bond2.201
# ==========================================
# Bond 3: GPU RDMA (ens320 + ens321) MTU 9000
# ==========================================
- name: ens320
type: ethernet
state: up
mtu: 9000
ipv4:
enabled: false
ipv6:
enabled: false
- name: ens321
type: ethernet
state: up
mtu: 9000
ipv4:
enabled: false
ipv6:
enabled: false
- name: bond3
type: bond
state: up
mtu: 9000
ipv4:
enabled: true
dhcp: false
address:
- ip: 10.50.0.10
prefix-length: 24
ipv6:
enabled: false
link-aggregation:
mode: 802.3ad
options:
miimon: "100"
xmit_hash_policy: "layer3+4"
port:
- ens320
- ens321
# ==========================================
# Routing
# ==========================================
routes:
config:
# Default gateway via management bond
- destination: 0.0.0.0/0
next-hop-address: 10.0.1.1
next-hop-interface: bond0
metric: 100
# Storage network routes
- destination: 10.200.0.0/16
next-hop-address: 10.100.0.1
next-hop-interface: bond1.100
metric: 100
# GPU cluster routes
- destination: 10.50.0.0/16
next-hop-address: 10.50.0.1
next-hop-interface: bond3
metric: 100
dns-resolver:
config:
server:
- 10.0.1.53
- 10.0.1.54
search:
- cluster.internal.example.comNetworkAttachmentDefinitions
Create NADs to expose these networks to pods:
# Storage network for Ceph
apiVersion: k8s.cni.cncf.io/v1
kind: NetworkAttachmentDefinition
metadata:
name: storage-ceph
namespace: openshift-storage
spec:
config: |
{
"cniVersion": "0.3.1",
"type": "macvlan",
"master": "bond1.100",
"mode": "bridge",
"mtu": 9000,
"ipam": {
"type": "whereabouts",
"range": "10.100.0.0/24",
"exclude": ["10.100.0.1/32", "10.100.0.0/28"]
}
}
---
# Tenant A VM network
apiVersion: k8s.cni.cncf.io/v1
kind: NetworkAttachmentDefinition
metadata:
name: tenant-a-network
namespace: tenant-a
spec:
config: |
{
"cniVersion": "0.3.1",
"type": "bridge",
"bridge": "br-tenant-a",
"ipam": {}
}
---
# GPU RDMA network
apiVersion: k8s.cni.cncf.io/v1
kind: NetworkAttachmentDefinition
metadata:
name: gpu-rdma
namespace: ai-workloads
spec:
config: |
{
"cniVersion": "0.3.1",
"type": "macvlan",
"master": "bond3",
"mode": "bridge",
"mtu": 9000,
"ipam": {
"type": "whereabouts",
"range": "10.50.0.0/24",
"exclude": ["10.50.0.1/32", "10.50.0.0/28"]
}
}Verification
# Check all bonds
for bond in bond0 bond1 bond2 bond3; do
echo "=== $bond ==="
oc debug node/worker-0 -- chroot /host cat /proc/net/bonding/$bond 2>/dev/null | head -10
done
# Check all VLANs
oc debug node/worker-0 -- chroot /host ls /proc/net/vlan/
# Check bridges
oc debug node/worker-0 -- chroot /host bridge link show
# Check routes
oc debug node/worker-0 -- chroot /host ip route show
# Check MTU on all interfaces
oc debug node/worker-0 -- chroot /host ip -o link show | awk '{print $2, $(NF-1), $NF}'flowchart TD
A[Worker Node - 8 NICs] --> B[bond0 - Management]
A --> C[bond1 - Storage MTU 9000]
A --> D[bond2 - Tenant and VM]
A --> E[bond3 - GPU RDMA MTU 9000]
B --> F[10.0.1.x - API, kubelet]
C --> G[VLAN 100 - Ceph Public]
C --> H[VLAN 101 - Ceph Cluster]
D --> I[VLAN 200 - br-tenant-a]
D --> J[VLAN 201 - br-tenant-b]
I --> K[KubeVirt VMs]
J --> K
E --> L[10.50.0.x - NCCL, RDMA]
G --> M[10.100.0.x]
H --> N[10.101.0.x]Common Issues
Too many interfaces cause NNCP timeout
# Large NNCPs with many interfaces take longer to apply
# Increase the rollback timeout
metadata:
annotations:
nmstate.io/rollback-timeout: "480"Interface names differ across node hardware
# Use consistent naming via udev rules or
# Create per-node NNCPs with hostname selectors
# List interfaces on all workers to find discrepancies
for node in $(oc get nodes -l node-role.kubernetes.io/worker -o name); do
echo "=== $node ==="
oc get nns $(basename $node) -o jsonpath='{.status.currentState.interfaces[*].name}' | tr ' ' '\n' | grep -E '^(ens|eth|enp)'
doneBond and VLAN ordering issues
# The nmstate operator handles dependency ordering
# But ensure the NNCP defines interfaces in order:
# 1. Physical NICs (ports)
# 2. Bonds (using the physical NICs)
# 3. VLANs (on bonds)
# 4. Bridges (on VLANs)Best Practices
- Separate traffic classes onto separate bonds β management, storage, tenant, GPU should never share NICs
- Use active-backup for management β simplest, no switch config needed, protects API connectivity
- Use 802.3ad (LACP) for data bonds β storage and GPU benefit from aggregated bandwidth
- Jumbo frames only on storage and GPU β keep management at MTU 1500
- Use per-node NNCPs for unique IPs β share a common NNCP template but customize per hostname
- Roll out one node at a time β always set
maxUnavailable: 1for multi-NIC changes - Test the complete stack β verify bond, VLAN, bridge, and routing together before production
- Document the architecture β create a network diagram mapping NICs to bonds to VLANs to bridges
Key Takeaways
- A production multi-NIC architecture uses 4 bond pairs (8 NICs) for full traffic separation
- Stack layers as: physical NIC β bond β VLAN β bridge (for VM access)
- Management uses active-backup (no switch config), data networks use 802.3ad (LACP)
- Jumbo frames (MTU 9000) on storage and GPU networks, standard MTU on management
- Use NetworkAttachmentDefinitions with Multus to expose each network to pods and VMs
- NNCP handles the full stack declaratively β from physical NIC configuration to routing and DNS

Recommended
Kubernetes Recipes β The Complete Book100+ production-ready patterns with detailed explanations, best practices, and copy-paste YAML. Everything in one place.
Get the Book βLearn by Doing
CopyPasteLearn β Hands-on Cloud & DevOps CoursesMaster Kubernetes, Ansible, Terraform, and MLOps with interactive, copy-paste-run lessons. Start free.
Browse Courses βπ Deepen Your Skills β Hands-on Courses
Courses by CopyPasteLearn.com β Learn IT by Doing