π‘ Quick Answer: The SR-IOV Network Operator on OpenShift manages Mellanox ConnectX RDMA/InfiniBand devices via
SriovNetworkNodePolicy. When the device plugin logs βno devices in device pool, skipping creating resource server for mellanoxnics,β it means the policyβs selector doesnβt match available VFs β verify PCI addresses, numVfs, and node labels.
The Problem
Setting up SR-IOV with RDMA/InfiniBand for GPU workloads (NCCL, tensor parallelism) requires:
- Correct SriovNetworkNodePolicy targeting Mellanox ConnectX NICs
- Virtual Functions (VFs) created and bound to the correct driver
- Device plugin exposing
/dev/infiniband/uverbs*and/dev/infiniband/rdma_cmto Pods - Troubleshooting when devices arenβt registered in the resource pool
The Solution
SriovNetworkNodePolicy for Mellanox RDMA
apiVersion: sriovnetwork.openshift.io/v1
kind: SriovNetworkNodePolicy
metadata:
name: mellanox-rdma-policy
namespace: openshift-sriov-network-operator
spec:
nodeSelector:
feature.node.kubernetes.io/pci-15b3.present: "true"
numVfs: 16
priority: 98
resourceName: mellanoxnics
vendor: "15b3"
deviceType: netdevice
isRdma: true
nicSelector:
vendor: "15b3"
# Optional: target specific PF by PCI address
# rootDevices:
# - "0000:ca:00.0"
# - "0001:c8:00.0"
# Or by pfNames:
# pfNames:
# - "ens1f0np0"
# - "ens2f0np0"Verify SR-IOV Operator Components
# Check all SR-IOV operator Pods are running
oc get pods -n openshift-sriov-network-operator -o wide
# Expected Pods:
# - sriov-network-operator (1 replica)
# - sriov-device-plugin (DaemonSet, per GPU node)
# - sriov-network-config-daemon (DaemonSet, per GPU node)
# - network-resources-injector (3 replicas)
# - operator-webhook (3 replicas)
# Check node state
oc get sriovnetworknodestates -n openshift-sriov-network-operator
# Detailed node state (shows discovered devices)
oc get sriovnetworknodestates <node-name> -o yamlVerify Device Discovery
# Check what the device plugin discovers
oc logs sriov-device-plugin-<hash> -n openshift-sriov-network-operator
# Successful discovery shows:
# auxNetDeviceProvider AddTargetDevices(): device found: 0000:c8:00.0 02
# Mellanox Technology MT2894 Family [ConnectX-6 Lx]
# auxNetDeviceProvider AddTargetDevices(): device found: 0000:ca:00.0 02
# Mellanox Technology MT2910 Family [ConnectX-7]
# Check network config daemon for VF creation
oc logs sriov-network-config-daemon-<hash> -n openshift-sriov-network-operatorUnderstand Device Allocation Flow
Allocation Request Flow:
βββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββ
1. Pod requests: resources.requests["openshift.io/mellanoxnics"]: "1"
2. Device Plugin receives AllocateRequest
β server.go:127 Allocate() called with &AllocateRequest
β pool_stub.go:108 GetEnvs(): for devices: [0000:ca:00.7]
3. Device Plugin resolves device specs
β netResourcePool.go:89 GetDeviceSpecs(): for devices: [0000:ca:00.7]
β rdmaInfoProvider.go:57 GetRdmaDeviceSpec() returned:
β’ ContainerPath: /dev/infiniband/uverbs31
β’ HostPath: /dev/infiniband/uverbs31
β’ ContainerPath: /dev/infiniband/rdma_cm
β’ HostPath: /dev/infiniband/rdma_cm
4. AllocateResponse sent back with:
β’ PCIDEVICE_OPENSHIFT_IO_MELLANOXNICS_INFO env var (JSON)
β’ Device mounts: /dev/infiniband/uverbs*, /dev/infiniband/rdma_cm
β’ CDI devices (if CDI mode enabled)
5. Pod starts with RDMA devices mountedDevice Info Environment Variable
// PCIDEVICE_OPENSHIFT_IO_MELLANOXNICS_INFO (injected into Pod)
{
"0000:ca:00.7": {
"generic": {
"deviceID": "0000:ca:00.7"
},
"rdma": {
"rdma_cm": "/dev/infiniband/rdma_cm"
}
}
}SriovNetwork for Pod Attachment
apiVersion: sriovnetwork.openshift.io/v1
kind: SriovNetwork
metadata:
name: rdma-network
namespace: openshift-sriov-network-operator
spec:
networkNamespace: ai-training
resourceName: mellanoxnics
ipam: |
{
"type": "whereabouts",
"range": "192.168.100.0/24"
}
capabilities: '{"rdma": true}'
---
# Pod requesting SR-IOV RDMA device
apiVersion: v1
kind: Pod
metadata:
name: nccl-test
namespace: ai-training
annotations:
k8s.v1.cni.cncf.io/networks: rdma-network
spec:
containers:
- name: nccl
image: nvcr.io/nvidia/pytorch:24.07-py3
resources:
requests:
nvidia.com/gpu: "1"
openshift.io/mellanoxnics: "1"
limits:
nvidia.com/gpu: "1"
openshift.io/mellanoxnics: "1"
env:
- name: NCCL_IB_HCA
value: "mlx5"
- name: NCCL_DEBUG
value: "INFO"Troubleshooting: βno devices in device poolβ
# Error in device plugin logs:
# "no devices in device pool, skipping creating resource server for mellanoxnics"
# Root Causes:
# 1. VFs not created yet
# Check if numVfs are configured on the PF
oc debug node/<gpu-node> -- chroot /host cat /sys/class/net/ens1f0np0/device/sriov_numvfs
# Should show: 16 (matching your policy)
# 2. Node doesn't match nodeSelector
oc get nodes --show-labels | grep "pci-15b3"
# Verify: feature.node.kubernetes.io/pci-15b3.present=true
# 3. PCI vendor/device mismatch
# Check actual PCI devices on node
oc debug node/<gpu-node> -- chroot /host lspci -nn | grep Mellanox
# Look for vendor 15b3
# 4. Driver binding issue (VFs exist but not bound)
oc debug node/<gpu-node> -- chroot /host ls /sys/class/infiniband/
# Should show: mlx5_0, mlx5_1, ... mlx5_N
# 5. Config daemon hasn't applied yet
oc get sriovnetworknodestates <node> -n openshift-sriov-network-operator -o yaml
# Check: status.syncStatus should be "Succeeded"
# 6. Selector too restrictive (rootDevices/pfNames don't match)
# Remove rootDevices/pfNames from policy to use all 15b3 devicesTroubleshooting: Device Plugin Allocation Errors
# Check device plugin detailed logs
oc logs -n openshift-sriov-network-operator \
$(oc get pods -n openshift-sriov-network-operator -l app=sriov-device-plugin \
--field-selector spec.nodeName=<gpu-node> -o name) -f
# Verify allocatable resources on node
oc describe node <gpu-node> | grep -A5 "Allocatable"
# Should show: openshift.io/mellanoxnics: 16
# Check if resources are already consumed
oc describe node <gpu-node> | grep -A5 "Allocated resources"
# Verify RDMA device files exist on node
oc debug node/<gpu-node> -- chroot /host ls -la /dev/infiniband/
# Should show: rdma_cm, uverbs0, uverbs1, ... uverbsNConnectX NIC Family Reference
Device ID Family Speed Common Use
βββββββββββββββββββββββββββββββββββββββββββββββββββββββββ
MT27800 ConnectX-5 100Gb/s InfiniBand EDR
MT28800 ConnectX-5 Ex 100Gb/s InfiniBand EDR
MT2892 ConnectX-6 200Gb/s InfiniBand HDR
MT2894 ConnectX-6 Lx 100Gb/s Ethernet only
MT2910 ConnectX-7 400Gb/s InfiniBand NDR
MT2920 ConnectX-7 400Gb/s InfiniBand NDR
Vendor ID: 15b3 (Mellanox Technologies / NVIDIA Networking)Multi-Device Allocation (Multiple RDMA VFs per Pod)
# For multi-GPU Pods needing multiple RDMA paths
apiVersion: v1
kind: Pod
metadata:
name: distributed-training
annotations:
k8s.v1.cni.cncf.io/networks: |
[
{"name": "rdma-network", "interface": "net1"},
{"name": "rdma-network", "interface": "net2"}
]
spec:
containers:
- name: training
image: nvcr.io/nvidia/pytorch:24.07-py3
resources:
requests:
nvidia.com/gpu: "4"
openshift.io/mellanoxnics: "4"
limits:
nvidia.com/gpu: "4"
openshift.io/mellanoxnics: "4"
env:
- name: NCCL_IB_HCA
value: "mlx5"
- name: NCCL_NET_GDR_LEVEL
value: "5"
- name: NCCL_IB_GID_INDEX
value: "3"Common Issues
VFs created but not visible to device plugin
- Cause: Config daemon applied VFs but device plugin started before
- Fix: Restart device plugin Pod:
oc delete pod sriov-device-plugin-<hash> -n openshift-sriov-network-operator
RDMA devices missing after node reboot
- Cause: VF configuration not persisted in MachineConfig
- Fix: SR-IOV operator should persist via config daemon; check
syncStatus
Mixed ConnectX-6 and ConnectX-7 β policy applies to wrong NICs
- Cause: Vendor-only selector matches all Mellanox NICs
- Fix: Use
pfNamesorrootDevicesin nicSelector to target specific PFs
NCCL fails with βNo RDMA device foundβ
- Cause: Pod doesnβt have RDMA devices mounted or wrong HCA name
- Fix: Verify
openshift.io/mellanoxnicsin Pod spec; check/dev/infiniband/inside Pod
Best Practices
- Use
feature.node.kubernetes.io/pci-15b3.presentas nodeSelector β auto-detected by NFD - Start with numVfs: 16 β enough for most GPU training workloads
- Set priority: 98 β below default (99) to not conflict with other policies
- Enable
isRdma: trueβ mounts uverbs + rdma_cm into Pods - One policy per NIC type β separate ConnectX-6 Lx (Ethernet) from ConnectX-7 (IB)
- Monitor with
oc get sriovnetworknodestatesβ shows sync status per node - Match RDMA VFs to GPUs β 1 VF per GPU for optimal NCCL topology
Key Takeaways
- SR-IOV device plugin allocates RDMA devices (/dev/infiniband/uverbs*, rdma_cm) to Pods
- βNo devices in device poolβ = VFs not created, node label missing, or selector mismatch
- Device allocation injects PCIDEVICE env var with device-to-RDMA mapping
- ConnectX-6/6Lx/7 all use vendor 15b3; differentiate by pfNames or rootDevices
- NCCL needs
NCCL_IB_HCA=mlx5+ SR-IOV VF for GPU-Direct RDMA - Check
sriovnetworknodestatesfor sync status; device plugin logs for allocation flow - Multi-GPU Pods request multiple VFs (1:1 GPU-to-RDMA for optimal topology)

Recommended
Kubernetes Recipes β The Complete Book100+ production-ready patterns with detailed explanations, best practices, and copy-paste YAML. Everything in one place.
Get the Book βLearn by Doing
CopyPasteLearn β Hands-on Cloud & DevOps CoursesMaster Kubernetes, Ansible, Terraform, and MLOps with interactive, copy-paste-run lessons. Start free.
Browse Courses βπ Deepen Your Skills β Hands-on Courses
Courses by CopyPasteLearn.com β Learn IT by Doing