PFC Configuration on Mellanox ConnectX NICs
Enable Priority Flow Control on Mellanox ConnectX-6/7 NICs for lossless RoCE. mlnx_qos, cma_roce_mode, DSCP trust, ECN, and firmware-level PFC verification.
π‘ Quick Answer: Enable PFC on Mellanox ConnectX NICs using
mlnx_qos -i <interface> --pfc 0,0,0,1,0,0,0,0to make priority 3 lossless (RoCE default). Set DSCP trust mode withmlnx_qos -i <interface> --trust dscpso packets are classified by DSCP value (26/AF31 β priority 3). Verify withmlnx_qos -i <interface>and check PFC counters viaethtool -S <interface> | grep prio3.
The Problem
RoCE (RDMA over Converged Ethernet) requires a lossless network fabric. Unlike InfiniBand which is lossless by design, Ethernet drops packets under congestion. PFC (Priority Flow Control / IEEE 802.1Qbb) pauses specific traffic classes when buffers fill, preventing drops. Without PFC, RoCE performance degrades severely β NCCL all-reduce operations retry endlessly, GPU training throughput collapses.
flowchart LR
subgraph WITHOUT["Without PFC"]
GPU1A["GPU"] -->|"RDMA write"| NIC1A["NIC"]
NIC1A -->|"Packet"| SW1A["Switch<br/>buffer full"]
SW1A -->|"β DROP"| NIC2A["NIC"]
NIC2A --> GPU2A["GPU"]
end
subgraph WITH["With PFC"]
GPU1B["GPU"] -->|"RDMA write"| NIC1B["NIC"]
NIC1B -->|"Packet"| SW1B["Switch<br/>buffer filling"]
SW1B -->|"βΈοΈ PAUSE<br/>priority 3"| NIC1B
SW1B -->|"Buffer drains"| NIC2B["NIC"]
NIC2B --> GPU2B["GPU"]
endPrerequisites
# Check NIC model
lspci | grep Mellanox
# 86:00.0 Ethernet controller: Mellanox Technologies MT2910 Family [ConnectX-7]
# Check firmware version (PFC requires firmware support)
ethtool -i ens8f0np0
# driver: mlx5_core
# version: 5.9-0.5.9.0
# firmware-version: 28.39.1002
# Install Mellanox tools (if not present)
# RHEL/Rocky:
yum install -y mstflint mlnx-tools
# Ubuntu:
apt install -y mstflint mlnx-toolsStep 1: Set Trust Mode to DSCP
By default, NICs trust PCP (VLAN priority bits / Layer 2). For RoCE, you want DSCP trust (Layer 3) β works without VLAN tagging:
# Check current trust mode
mlnx_qos -i ens8f0np0
# Trust state: pcp β Default, Layer 2 (requires VLAN tags)
# Switch to DSCP trust
mlnx_qos -i ens8f0np0 --trust dscp
# Trust state: dscp β Now classifies by IP DSCP field
# Verify
mlnx_qos -i ens8f0np0 | grep -i trust
# Trust state: dscpWhy DSCP Over PCP?
| Mode | Layer | Requires VLAN | Works Routed | RoCE Default |
|---|---|---|---|---|
| PCP (802.1p) | L2 | β Yes | β No | No |
| DSCP | L3 | β No | β Yes | Yes |
RoCE v2 sets DSCP 26 (AF31) by default β maps to priority 3. DSCP trust reads this value and places traffic in the correct queue.
Step 2: Enable PFC on Priority 3
# Current PFC state (all disabled by default)
mlnx_qos -i ens8f0np0
# PFC configuration:
# priority: 0 1 2 3 4 5 6 7
# enabled: 0 0 0 0 0 0 0 0
# Enable PFC on priority 3 ONLY
mlnx_qos -i ens8f0np0 --pfc 0,0,0,1,0,0,0,0
# PFC configuration:
# priority: 0 1 2 3 4 5 6 7
# enabled: 0 0 0 1 0 0 0 0
# β οΈ Do NOT enable PFC on all priorities β wastes buffer space
# Only priority 3 needs to be lossless for RoCEUnderstanding the Priority Mapping
DSCP 26 (AF31) β Traffic Class 3 β Priority 3 β PFC enabled
β
LOSSLESS β
DSCP 0 (Best Effort) β Traffic Class 0 β Priority 0 β PFC disabled
β
LOSSY (normal) β
Step 3: Configure ETS (Enhanced Transmission Selection)
ETS allocates bandwidth between traffic classes:
# Check current ETS
mlnx_qos -i ens8f0np0
# tc: 0 1 2 3 4 5 6 7
# bw: 100 0 0 0 0 0 0 0 β All bandwidth on TC0
# Allocate 30% to RoCE (TC3), 70% to best-effort (TC0)
mlnx_qos -i ens8f0np0 \
--tc_bw 70,0,0,30,0,0,0,0 \
--tsa ets,strict,strict,ets,strict,strict,strict,strict
# tsa options:
# ets = Enhanced Transmission Selection (bandwidth guaranteed)
# strict = Strict priority (always served first if queued)
# Verify
mlnx_qos -i ens8f0np0
# ETS/BW:
# tc: 0 1 2 3 4 5 6 7
# bw: 70 0 0 30 0 0 0 0
# tsa: ets str str ets str str str strStep 4: Map DSCP to Priority
Ensure DSCP 26 (decimal) maps to priority 3:
# Show current DSCP-to-priority mapping
mlnx_qos -i ens8f0np0 --dscp2prio
# DSCP Priority
# 0 0
# ...
# 26 3 β Should be 3 (default for RoCE)
# ...
# If mapping is wrong, set it explicitly:
mlnx_qos -i ens8f0np0 --dscp2prio set,26,3
# For GDR (GPUDirect RDMA) traffic which may use different DSCP:
mlnx_qos -i ens8f0np0 --dscp2prio set,24,3 # CS3 β priority 3
mlnx_qos -i ens8f0np0 --dscp2prio set,26,3 # AF31 β priority 3
mlnx_qos -i ens8f0np0 --dscp2prio set,34,3 # AF41 β priority 3Step 5: Enable ECN (Explicit Congestion Notification)
ECN works alongside PFC β marks packets instead of dropping, reducing PFC pause frame frequency:
# Enable ECN on TC3 (RoCE traffic class)
echo 1 > /sys/class/net/ens8f0np0/ecn/roce_np/enable/3
echo 1 > /sys/class/net/ens8f0np0/ecn/roce_rp/enable/3
# Set ECN thresholds (in KB)
# min_threshold: Start marking ECN at this buffer level
# max_threshold: Mark all packets above this level
echo 150 > /sys/class/net/ens8f0np0/ecn/roce_np/min_threshold/3 # 150KB
echo 1500 > /sys/class/net/ens8f0np0/ecn/roce_np/max_threshold/3 # 1500KB
# Verify ECN
cat /sys/class/net/ens8f0np0/ecn/roce_np/enable/3
# 1
cat /sys/class/net/ens8f0np0/ecn/roce_rp/enable/3
# 1PFC + ECN Together
flowchart LR
NORMAL["Buffer OK"] -->|"Buffer 30%"| ECN_MARK["ECN Mark<br/>(slow down)"]
ECN_MARK -->|"Buffer 80%"| PFC_PAUSE["PFC Pause<br/>(stop sending)"]
PFC_PAUSE -->|"Buffer 95%"| DROP["DROP<br/>(last resort)"]
style NORMAL fill:#2ecc71
style ECN_MARK fill:#f39c12
style PFC_PAUSE fill:#e74c3c
style DROP fill:#000,color:#fffECN reacts before PFC kicks in β fewer pause frames β better throughput.
Step 6: Configure RoCE Mode
# Check current RoCE mode
cma_roce_mode -d mlx5_0
# RoCE mode: RoCE v2 β Correct (uses UDP/IP, DSCP-aware)
# If it shows RoCE v1, switch to v2:
cma_roce_mode -d mlx5_0 -m 2
# Verify
cma_roce_mode -d mlx5_0
# RoCE mode: RoCE v2| RoCE Version | Layer | DSCP Support | Routable | Use When |
|---|---|---|---|---|
| RoCE v1 | L2 (Ethertype) | β No | β Same subnet | Legacy only |
| RoCE v2 | L3 (UDP:4791) | β Yes | β Routed | Always |
Verification
Check PFC Configuration
# Full QoS dump
mlnx_qos -i ens8f0np0
# Trust state: dscp
# PFC configuration:
# priority: 0 1 2 3 4 5 6 7
# enabled: 0 0 0 1 0 0 0 0
# ETS/BW:
# tc: 0 1 2 3 4 5 6 7
# bw: 70 0 0 30 0 0 0 0
# tsa: ets str str ets str str str strCheck PFC Counters
# PFC pause frames sent/received
ethtool -S ens8f0np0 | grep prio3
# rx_prio3_pause: 142 β Pause frames received (switch told us to pause)
# tx_prio3_pause: 87 β Pause frames sent (we told switch to pause)
# rx_prio3_bytes: 5849302847
# tx_prio3_bytes: 4928100234
# Non-zero pause counters = PFC is working
# Very high pause counts = congestion β check switch buffers or ECN thresholds
# Compare with lossy priorities (should have no pause frames)
ethtool -S ens8f0np0 | grep prio0
# rx_prio0_pause: 0 β No PFC on priority 0 (expected)
# tx_prio0_pause: 0Check for Drops (Should Be Zero on Priority 3)
# Check for drops on the RDMA interface
ethtool -S ens8f0np0 | grep -E "drop|discard"
# rx_discards_phy: 0 β β
No drops
# tx_discards_phy: 0
# Per-priority drops
ethtool -S ens8f0np0 | grep prio3_discard
# rx_prio3_discards: 0 β β
Lossless working
# If you see drops on priority 3, PFC is not working end-to-end
# Check: NIC config β cable β switch port β switch QoSRDMA Connectivity Test
# On server 1 (receiver):
ib_write_bw -d mlx5_0 --report_gbits
# On server 2 (sender):
ib_write_bw -d mlx5_0 10.10.1.10 --report_gbits
# Bandwidth: 195.4 Gb/s β Near line-rate for 200Gb HDR
# If bandwidth is significantly lower, check PFC counters
# High pause count = congestion somewhere in the pathMake Configuration Persistent
mlnx_qos settings are lost on reboot. Persist them:
Option A: NetworkManager Dispatcher Script
cat > /etc/NetworkManager/dispatcher.d/99-rdma-qos << 'EOF'
#!/bin/bash
# Persist PFC/QoS settings for RDMA interfaces
IFACE=$1
ACTION=$2
if [[ "$ACTION" == "up" && "$IFACE" =~ ^ens[0-9]+f[0-9]+ ]]; then
sleep 2 # Wait for interface to fully initialize
mlnx_qos -i "$IFACE" --trust dscp
mlnx_qos -i "$IFACE" --pfc 0,0,0,1,0,0,0,0
mlnx_qos -i "$IFACE" --tc_bw 70,0,0,30,0,0,0,0 --tsa ets,strict,strict,ets,strict,strict,strict,strict
# ECN
echo 1 > /sys/class/net/"$IFACE"/ecn/roce_np/enable/3
echo 1 > /sys/class/net/"$IFACE"/ecn/roce_rp/enable/3
logger "RDMA QoS configured for $IFACE"
fi
EOF
chmod +x /etc/NetworkManager/dispatcher.d/99-rdma-qosOption B: systemd Service
cat > /etc/systemd/system/rdma-qos.service << 'EOF'
[Unit]
Description=Configure RDMA PFC/QoS on Mellanox NICs
After=network-online.target
Wants=network-online.target
[Service]
Type=oneshot
RemainAfterExit=yes
ExecStart=/usr/local/bin/configure-rdma-qos.sh
[Install]
WantedBy=multi-user.target
EOF
cat > /usr/local/bin/configure-rdma-qos.sh << 'EOF'
#!/bin/bash
set -euo pipefail
# Configure all Mellanox interfaces
for iface in $(ls /sys/class/net/ | grep -E '^ens[0-9]+f'); do
if ethtool -i "$iface" 2>/dev/null | grep -q mlx5_core; then
echo "Configuring PFC/QoS on $iface"
mlnx_qos -i "$iface" --trust dscp
mlnx_qos -i "$iface" --pfc 0,0,0,1,0,0,0,0
mlnx_qos -i "$iface" --tc_bw 70,0,0,30,0,0,0,0 \
--tsa ets,strict,strict,ets,strict,strict,strict,strict
# ECN
echo 1 > /sys/class/net/"$iface"/ecn/roce_np/enable/3 2>/dev/null || true
echo 1 > /sys/class/net/"$iface"/ecn/roce_rp/enable/3 2>/dev/null || true
fi
done
EOF
chmod +x /usr/local/bin/configure-rdma-qos.sh
systemctl enable rdma-qos.serviceOption C: OpenShift MachineConfig
apiVersion: machineconfiguration.openshift.io/v1
kind: MachineConfig
metadata:
name: 99-rdma-pfc-qos
labels:
machineconfiguration.openshift.io/role: worker
spec:
config:
ignition:
version: 3.4.0
systemd:
units:
- name: rdma-qos.service
enabled: true
contents: |
[Unit]
Description=Configure RDMA PFC/QoS
After=network-online.target
[Service]
Type=oneshot
RemainAfterExit=yes
ExecStart=/usr/local/bin/configure-rdma-qos.sh
[Install]
WantedBy=multi-user.target
storage:
files:
- path: /usr/local/bin/configure-rdma-qos.sh
mode: 0755
contents:
inline: |
#!/bin/bash
for iface in $(ls /sys/class/net/ | grep -E '^ens[0-9]+f'); do
if ethtool -i "$iface" 2>/dev/null | grep -q mlx5_core; then
mlnx_qos -i "$iface" --trust dscp
mlnx_qos -i "$iface" --pfc 0,0,0,1,0,0,0,0
mlnx_qos -i "$iface" --tc_bw 70,0,0,30,0,0,0,0 \
--tsa ets,strict,strict,ets,strict,strict,strict,strict
echo 1 > /sys/class/net/"$iface"/ecn/roce_np/enable/3 2>/dev/null || true
echo 1 > /sys/class/net/"$iface"/ecn/roce_rp/enable/3 2>/dev/null || true
fi
doneSwitch-Side Configuration (Must Match)
PFC must be enabled end-to-end: NIC β switch port β switch β switch port β NIC.
# Cumulus Linux / NVIDIA Spectrum
cat /etc/cumulus/datapath/traffic.conf
# PFC on priority 3
pfc.pfc_en = 0,0,0,1,0,0,0,0
# Mellanox ONYX (SN series)
interface ethernet 1/1-1/32 traffic-class 3 dcb pfc mode on
# Cisco Nexus
interface Ethernet1/1
priority-flow-control mode on
priority-flow-control priority 3 no-drop
# Arista EOS
interface Ethernet1
priority-flow-control on
priority-flow-control priority 3 no-dropβ οΈ If the switch doesnβt have PFC enabled on priority 3, NIC-side PFC alone does nothing. PFC is a hop-by-hop protocol β every device in the path must participate.
Common Issues
| Issue | Cause | Fix |
|---|---|---|
mlnx_qos: command not found | mlnx-tools not installed | yum install mlnx-tools or apt install mlnx-tools |
| PFC counters stay 0 | Switch-side PFC not enabled | Configure switch QoS to match |
| Drops on priority 3 | PFC not working end-to-end | Check every hop: NIC β cable β switch β NIC |
| Trust mode resets after reboot | Not persisted | Use systemd service or MachineConfig |
| Low RDMA bandwidth | PFC storms (too many pauses) | Enable ECN, increase switch buffer, check for congestion |
cma_roce_mode not found | rdma-core or libibverbs-utils missing | Install RDMA userspace tools |
| Wrong DSCP on wire | Application overrides DSCP | Check NCCL_IB_TC env var, set to 106 (DSCP 26 in TOS) |
Best Practices
- PFC on priority 3 only β donβt make all priorities lossless (wastes buffer)
- Always use DSCP trust β works without VLANs, survives routing
- Enable ECN alongside PFC β reduces PFC storm frequency
- Match NIC and switch config exactly β PFC is hop-by-hop
- Monitor PFC pause counters β high counts indicate congestion
- Persist configuration β mlnx_qos is lost on reboot
- Test with ib_write_bw before deploying AI workloads β verify line-rate bandwidth
- Use RoCE v2 always β v1 is L2 only, canβt route, no DSCP support
Key Takeaways
- PFC makes Ethernet lossless for specific priorities β essential for RoCE/RDMA
mlnx_qos -i <iface> --trust dscp --pfc 0,0,0,1,0,0,0,0β the core commands- DSCP 26 (AF31) β priority 3 β PFC enabled β lossless RoCE
- ECN reduces PFC storms by signaling congestion before buffers fill
- Configuration must match end-to-end: NIC β switch β NIC
- Settings are NOT persistent β use systemd, MachineConfig, or dispatcher scripts
- Verify with
ethtool -S <iface> | grep prio3_pauseβ non-zero = PFC working

Recommended
Kubernetes Recipes β The Complete Book100+ production-ready patterns with detailed explanations, best practices, and copy-paste YAML. Everything in one place.
Get the Book βLearn by Doing
CopyPasteLearn β Hands-on Cloud & DevOps CoursesMaster Kubernetes, Ansible, Terraform, and MLOps with interactive, copy-paste-run lessons. Start free.
Browse Courses βπ Deepen Your Skills β Hands-on Courses
Courses by CopyPasteLearn.com β Learn IT by Doing