SR-IOV NicClusterPolicy for VF Configuration
Configure SR-IOV Virtual Functions on Mellanox ConnectX NICs using the NVIDIA Network Operator NicClusterPolicy for high-performance Kubernetes networking.
π‘ Quick Answer: Define a NicClusterPolicy with SR-IOV device plugin and configure an SriovNetworkNodePolicy to create Virtual Functions on specific PCI devices, then attach VFs to pods via NetworkAttachmentDefinitions.
The Problem
High-performance AI and HPC workloads need dedicated network interfaces with bare-metal performance inside pods. Standard CNI networking adds overhead through software bridges and kernel network stacks.
SR-IOV (Single Root I/O Virtualization) solves this by creating Virtual Functions (VFs) from a physical NIC, giving each pod direct hardware access. But configuring SR-IOV on Kubernetes requires coordinating:
- VF creation on physical NICs across nodes
- Device plugin to expose VFs to the scheduler
- Network definitions for pods to consume VFs
- RDMA support for GPUDirect workloads
The Solution
Step 1: Verify SR-IOV Support
# Check if SR-IOV is enabled on the NIC
lspci -vvv | grep -i "single root"
# Expected: Single Root I/O Virtualization (SR-IOV)
# Verify IOMMU is enabled
dmesg | grep -i iommu
# Expected: IOMMU enabled
# Check current VF count
cat /sys/class/net/ens3f0np0/device/sriov_numvfs
# Expected: 0 (before configuration)
# Check max VF count
cat /sys/class/net/ens3f0np0/device/sriov_totalvfs
# Expected: 128 (depends on NIC model)Step 2: Install the NVIDIA Network Operator
helm repo add nvidia https://helm.ngc.nvidia.com/nvidia
helm repo update
helm install network-operator nvidia/network-operator \
-n nvidia-network-operator --create-namespace \
--set nfd.enabled=true \
--set sriovNetworkOperator.enabled=trueStep 3: Configure NicClusterPolicy
The NicClusterPolicy defines cluster-wide NIC configuration including MOFED, device plugins, and secondary networks:
apiVersion: mellanox.com/v1alpha1
kind: NicClusterPolicy
metadata:
name: nic-cluster-policy
spec:
ofedDriver:
image: mofed
repository: nvcr.io/nvstaging/mellanox
version: "24.07-0.6.1.0"
startupProbe:
initialDelaySeconds: 10
periodSeconds: 20
livenessProbe:
initialDelaySeconds: 30
periodSeconds: 30
sriovDevicePlugin:
image: sriov-network-device-plugin
repository: ghcr.io/k8snetworkplumbingwg
version: "v3.7.0"
config: |
{
"resourceList": [
{
"resourcePrefix": "nvidia.com",
"resourceName": "rdma_vf",
"selectors": {
"vendors": ["15b3"],
"devices": ["101e"],
"drivers": ["mlx5_core"],
"pfNames": ["ens3f0np0#0-7"],
"isRdma": true
}
},
{
"resourcePrefix": "nvidia.com",
"resourceName": "eth_vf",
"selectors": {
"vendors": ["15b3"],
"devices": ["101e"],
"drivers": ["mlx5_core"],
"pfNames": ["ens3f1np1#0-7"],
"isRdma": false
}
}
]
}
secondaryNetwork:
cniPlugins:
image: plugins
repository: ghcr.io/k8snetworkplumbingwg
version: "v1.5.0"
multus:
image: multus-cni
repository: ghcr.io/k8snetworkplumbingwg
version: "v4.1.0"
ipamPlugin:
image: nvidia-k8s-ipam
repository: ghcr.io/mellanox
version: "v0.3.0"kubectl apply -f nic-cluster-policy.yamlStep 4: Create SriovNetworkNodePolicy
Define how many VFs to create and on which NICs:
apiVersion: sriovnetwork.openshift.io/v1
kind: SriovNetworkNodePolicy
metadata:
name: rdma-vfs
namespace: nvidia-network-operator
spec:
nodeSelector:
feature.node.kubernetes.io/network-sriov.capable: "true"
resourceName: rdma_vf
numVfs: 8
nicSelector:
vendor: "15b3"
pfNames:
- "ens3f0np0"
rootDevices:
- "0000:d8:00.0"
deviceType: netdevice
isRdma: true
linkType: ETH
mtu: 9000kubectl apply -f sriov-node-policy.yaml
# Monitor VF creation (node may reboot)
kubectl get sriovnetworknodestates -n nvidia-network-operator -wStep 5: Create NetworkAttachmentDefinition
apiVersion: k8s.cni.cncf.io/v1
kind: NetworkAttachmentDefinition
metadata:
name: rdma-net
namespace: default
annotations:
k8s.v1.cni.cncf.io/resourceName: nvidia.com/rdma_vf
spec:
config: |
{
"cniVersion": "0.3.1",
"name": "rdma-net",
"type": "host-device",
"ipam": {
"type": "nv-ipam",
"poolName": "rdma-pool"
}
}Step 6: Consume VFs in Pods
apiVersion: v1
kind: Pod
metadata:
name: rdma-workload
annotations:
k8s.v1.cni.cncf.io/networks: rdma-net
spec:
containers:
- name: worker
image: nvcr.io/nvidia/pytorch:24.07-py3
resources:
requests:
nvidia.com/rdma_vf: "1"
limits:
nvidia.com/rdma_vf: "1"
securityContext:
capabilities:
add: ["IPC_LOCK"]Step 7: Verify VF Assignment
# Check VFs are created on nodes
kubectl get sriovnetworknodestates -n nvidia-network-operator -o yaml | \
grep -A5 "numVfs"
# Check allocatable resources
kubectl get node <gpu-node> -o json | jq '.status.allocatable | with_entries(select(.key | contains("nvidia")))'
# Verify RDMA inside the pod
kubectl exec rdma-workload -- ibv_devices
kubectl exec rdma-workload -- ibv_devinfoflowchart TD
A[NicClusterPolicy] --> B[MOFED Driver DaemonSet]
A --> C[SR-IOV Device Plugin]
A --> D[Multus CNI]
E[SriovNetworkNodePolicy] -->|Create VFs| F["Physical NIC (PF)"]
F --> G[VF 0]
F --> H[VF 1]
F --> I[VF N]
C -->|Register| J[Kubelet Device Plugin API]
J -->|Allocate VF| K[Pod with RDMA Network]
D -->|Attach Network| KCommon Issues
VFs Not Created
# Check the SriovNetworkNodeState for errors
kubectl get sriovnetworknodestates -n nvidia-network-operator -o yaml
# Verify IOMMU is enabled in BIOS and kernel
cat /proc/cmdline | grep iommu
# Should contain: intel_iommu=on iommu=pt (Intel) or amd_iommu=on (AMD)Device Plugin Not Reporting Resources
# Check device plugin logs
kubectl logs -n nvidia-network-operator -l app=sriov-device-plugin
# Verify PCI vendor/device IDs match
lspci -nn | grep Mellanox
# Match the vendor (15b3) and device IDs in your configMTU Mismatch
VF MTU must not exceed PF MTU:
# Set PF MTU first
ip link set ens3f0np0 mtu 9000
# Then VFs inherit or can be set lower
ip link set ens3f0np0v0 mtu 9000Best Practices
- Pin PF names with PCI addresses β use
rootDevicesin addition topfNamesfor deterministic selection - Start with fewer VFs β begin with 4-8 VFs and increase based on workload density
- Enable RDMA only where needed β
isRdma: trueadds overhead; use plain VFs for non-RDMA workloads - Set MTU to 9000 for jumbo frames β required for optimal RDMA throughput
- Use nv-ipam for IP management β avoids conflicts with the primary CNI
- Label nodes β use node selectors to target only SR-IOV-capable hardware
Key Takeaways
- NicClusterPolicy configures the cluster-wide NIC stack: MOFED, SR-IOV device plugin, Multus, and IPAM
- SriovNetworkNodePolicy creates VFs on physical NICs β specify count, PCI address, and RDMA mode
- Pods consume VFs via
k8s.v1.cni.cncf.io/networksannotations and resource requests - Always verify with
ibv_devicesandibv_devinfoinside pods for RDMA workloads

Recommended
Kubernetes Recipes β The Complete Book100+ production-ready patterns with detailed explanations, best practices, and copy-paste YAML. Everything in one place.
Get the Book βLearn by Doing
CopyPasteLearn β Hands-on Cloud & DevOps CoursesMaster Kubernetes, Ansible, Terraform, and MLOps with interactive, copy-paste-run lessons. Start free.
Browse Courses βπ Deepen Your Skills β Hands-on Courses
Courses by CopyPasteLearn.com β Learn IT by Doing