NVIDIA DOCA Telemetry for Network Monitoring on Kubernetes
Deploy NVIDIA DOCA Telemetry Service (DTS) to collect real-time network metrics from BlueField DPUs and ConnectX NICs. Export RoCE counters, port
π‘ Quick Answer: NVIDIA DOCA Telemetry Service (DTS) runs on BlueField DPUs or host systems with ConnectX NICs to collect hardware-level network counters (port stats, RoCE metrics, congestion events, error rates) and exports them to Prometheus. Deploy as a DaemonSet on GPU worker nodes for full fabric observability.
The Problem
- GPU training jobs fail silently due to network degradation β no visibility into NIC-level stats
- RoCE congestion (ECN marks, PFC pauses) causes NCCL slowdowns but isnβt surfaced in standard monitoring
- Need hardware-level counters: port errors, packet drops, retransmits, bandwidth utilization
- Standard node_exporter doesnβt expose RDMA/InfiniBand/RoCE-specific metrics
- BlueField DPU telemetry requires specialized collection agents
The Solution
DOCA Telemetry Service Architecture
βββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββ
β GPU Worker Node β
β β
β ββββββββββββββββ βββββββββββββββββββββββββββββββββββ β
β β NCCL Traffic βββββΆβ ConnectX-7 / BlueField-3 DPU β β
β ββββββββββββββββ ββββββββββββ¬βββββββββββββββββββββββ β
β β hardware counters β
β ββββββββββββΌβββββββββββββββ β
β β DOCA Telemetry Service β β
β β (DTS container) β β
β β - Port counters β β
β β - RoCE/IB metrics β β
β β - PFC/ECN stats β β
β β - Error rates β β
β ββββββββββββ¬βββββββββββββββ β
β β :9090/metrics β
ββββββββββββββββββββββββββββββββββββΌββββββββββββββββββββββββββββ
βΌ
βββββββββββββββββββ
β Prometheus β
β + Grafana β
βββββββββββββββββββDeploy DOCA Telemetry as DaemonSet
apiVersion: apps/v1
kind: DaemonSet
metadata:
name: doca-telemetry
namespace: nvidia-network-operator
labels:
app: doca-telemetry
spec:
selector:
matchLabels:
app: doca-telemetry
template:
metadata:
labels:
app: doca-telemetry
annotations:
prometheus.io/scrape: "true"
prometheus.io/port: "9090"
prometheus.io/path: "/metrics"
spec:
nodeSelector:
nvidia.com/gpu.present: "true" # Only GPU nodes with NICs
tolerations:
- key: nvidia.com/gpu
operator: Exists
effect: NoSchedule
hostNetwork: true # Access host NIC counters
hostPID: true
containers:
- name: dts
image: nvcr.io/nvidia/doca/doca_telemetry:2.9.0
securityContext:
privileged: true # Required for hardware counter access
ports:
- containerPort: 9090
name: metrics
protocol: TCP
env:
- name: DTS_CONFIG_DIR
value: "/etc/dts"
- name: DTS_PROMETHEUS_PORT
value: "9090"
- name: DTS_COLLECTION_INTERVAL_MS
value: "1000" # 1-second collection interval
volumeMounts:
- name: dts-config
mountPath: /etc/dts
- name: sys
mountPath: /sys
readOnly: true
- name: infiniband
mountPath: /dev/infiniband
resources:
requests:
cpu: "100m"
memory: "256Mi"
limits:
cpu: "500m"
memory: "512Mi"
volumes:
- name: dts-config
configMap:
name: doca-telemetry-config
- name: sys
hostPath:
path: /sys
- name: infiniband
hostPath:
path: /dev/infinibandDTS Configuration
apiVersion: v1
kind: ConfigMap
metadata:
name: doca-telemetry-config
namespace: nvidia-network-operator
data:
dts_config.ini: |
[General]
# Collection interval in milliseconds
collection_interval=1000
# Export format
export_format=prometheus
prometheus_port=9090
[Counters]
# Enable all counter sources
enable_port_counters=true
enable_extended_counters=true
enable_rdma_counters=true
enable_pfc_counters=true
enable_congestion_counters=true
enable_error_counters=true
enable_temperature=true
[PortCounters]
# Standard port statistics
port_rcv_data=true
port_xmit_data=true
port_rcv_packets=true
port_xmit_packets=true
port_unicast_rcv_packets=true
port_unicast_xmit_packets=true
port_multicast_rcv_packets=true
port_multicast_xmit_packets=true
[RDMACounters]
# RoCE / InfiniBand specific
roce_adp_retrans=true
roce_adp_retrans_to=true
roce_slow_restart=true
roce_slow_restart_cnps=true
roce_slow_restart_trans=true
np_cnp_sent=true
rp_cnp_handled=true
np_ecn_marked_roce_packets=true
rx_read_requests=true
rx_write_requests=true
rx_atomic_requests=true
[PFCCounters]
# Priority Flow Control
rx_pause_duration=true
tx_pause_duration=true
rx_pause_transition=true
tx_pause_transition=true
# Per-priority (0-7)
rx_prio0_pause=true
tx_prio0_pause=true
rx_prio3_pause=true
tx_prio3_pause=true
[CongestionCounters]
# ECN and congestion signals
ecn_marked_packets=true
cnp_packets_received=true
cnp_packets_sent=true
congestion_events=true
[ErrorCounters]
# Errors and drops
port_rcv_errors=true
port_rcv_remote_physical_errors=true
port_rcv_switch_relay_errors=true
port_xmit_discards=true
port_xmit_constraint_errors=true
port_rcv_constraint_errors=true
symbol_error=true
link_downed=true
link_error_recovery=true
local_link_integrity_errors=true
excessive_buffer_overrun_errors=true
sources.yaml: |
# Define which devices to monitor
sources:
- type: connectx
devices: "all" # Monitor all ConnectX/BlueField ports
ports: "all" # All ports on each device
- type: host_counters
interfaces: "all" # Also collect host-level NIC statsPrometheus ServiceMonitor
apiVersion: monitoring.coreos.com/v1
kind: ServiceMonitor
metadata:
name: doca-telemetry
namespace: nvidia-network-operator
labels:
release: prometheus # Match your Prometheus operator selector
spec:
selector:
matchLabels:
app: doca-telemetry
endpoints:
- port: metrics
interval: 15s
path: /metrics
namespaceSelector:
matchNames:
- nvidia-network-operator
---
# Service for ServiceMonitor target discovery
apiVersion: v1
kind: Service
metadata:
name: doca-telemetry
namespace: nvidia-network-operator
labels:
app: doca-telemetry
spec:
clusterIP: None # Headless β one target per node
selector:
app: doca-telemetry
ports:
- name: metrics
port: 9090
targetPort: 9090Key Metrics Exposed
# Verify metrics are being collected
kubectl exec -n nvidia-network-operator ds/doca-telemetry -- \
curl -s localhost:9090/metrics | head -50
# Example metrics:
# HELP doca_port_rcv_data_bytes Total bytes received on port
# TYPE doca_port_rcv_data_bytes counter
doca_port_rcv_data_bytes{device="mlx5_0",port="1"} 8.234e+12
# HELP doca_roce_adp_retrans RoCE adaptive retransmissions
# TYPE doca_roce_adp_retrans counter
doca_roce_adp_retrans{device="mlx5_0",port="1"} 42
# HELP doca_np_cnp_sent Congestion Notification Packets sent
# TYPE doca_np_cnp_sent counter
doca_np_cnp_sent{device="mlx5_0",port="1"} 1523
# HELP doca_rx_pause_duration_us PFC pause duration in microseconds
# TYPE doca_rx_pause_duration_us counter
doca_rx_pause_duration_us{device="mlx5_0",port="1",priority="3"} 85432
# HELP doca_port_rcv_errors Total receive errors
# TYPE doca_port_rcv_errors counter
doca_port_rcv_errors{device="mlx5_0",port="1"} 0Prometheus Alert Rules for Network Health
apiVersion: monitoring.coreos.com/v1
kind: PrometheusRule
metadata:
name: doca-network-alerts
namespace: nvidia-network-operator
spec:
groups:
- name: gpu-network-health
rules:
# RoCE retransmissions indicate congestion or errors
- alert: HighRoCERetransmissions
expr: rate(doca_roce_adp_retrans[5m]) > 100
for: 2m
labels:
severity: warning
annotations:
summary: "High RoCE retransmissions on {{ $labels.device }}"
description: "Node {{ $labels.instance }} device {{ $labels.device }} has {{ $value }}/s retransmissions β check for cable issues or switch congestion."
# PFC pauses indicate back-pressure (network congestion)
- alert: ExcessivePFCPauses
expr: rate(doca_tx_pause_duration_us[5m]) > 10000
for: 5m
labels:
severity: warning
annotations:
summary: "Excessive PFC pause on {{ $labels.device }} priority {{ $labels.priority }}"
description: "PFC is throttling traffic β switch buffers may be full."
# Port errors indicate physical layer problems
- alert: PortReceiveErrors
expr: rate(doca_port_rcv_errors[5m]) > 0
for: 1m
labels:
severity: critical
annotations:
summary: "Port receive errors on {{ $labels.device }}"
description: "Physical layer errors detected β check cable, transceiver, or port."
# Link down events
- alert: LinkDown
expr: increase(doca_link_downed[5m]) > 0
for: 0m
labels:
severity: critical
annotations:
summary: "NIC link went down on {{ $labels.instance }}"
description: "Device {{ $labels.device }} experienced link down β NCCL jobs will fail."
# Low bandwidth utilization (possible misconfiguration)
- alert: LowFabricUtilization
expr: |
rate(doca_port_xmit_data_bytes[5m]) < 1e9
and on(instance) kube_node_labels{label_nvidia_com_gpu_present="true"}
for: 10m
labels:
severity: info
annotations:
summary: "GPU node {{ $labels.instance }} network underutilized"
description: "Less than 1 GB/s transmitted β verify NCCL is using the correct NIC."Grafana Dashboard Queries
# Throughput per NIC (GB/s)
rate(doca_port_xmit_data_bytes{device=~"mlx5_.*"}[1m]) / 1e9
# RoCE retransmission rate (should be near 0)
rate(doca_roce_adp_retrans[5m])
# PFC pause duration trending (microseconds/second)
rate(doca_tx_pause_duration_us[5m])
# ECN congestion events (CNPs sent = receiver saw ECN)
rate(doca_np_cnp_sent[5m])
# Packet error ratio
rate(doca_port_rcv_errors[5m]) / rate(doca_port_rcv_packets[5m])
# Total RDMA operations/sec
rate(doca_rx_read_requests[1m]) + rate(doca_rx_write_requests[1m])Verify on Host (Without DTS)
# Alternative: read counters directly from sysfs (no DTS needed)
# Port counters
cat /sys/class/infiniband/mlx5_0/ports/1/counters/port_rcv_data
cat /sys/class/infiniband/mlx5_0/ports/1/counters/port_xmit_data
cat /sys/class/infiniband/mlx5_0/ports/1/counters/port_rcv_errors
# RoCE-specific (extended hardware counters)
cat /sys/class/infiniband/mlx5_0/ports/1/hw_counters/roce_adp_retrans
cat /sys/class/infiniband/mlx5_0/ports/1/hw_counters/np_cnp_sent
cat /sys/class/infiniband/mlx5_0/ports/1/hw_counters/rp_cnp_handled
# PFC counters via ethtool
ethtool -S ens1f0np0 | grep pause
# rx_prio3_pause: 0
# tx_prio3_pause: 15234
# rx_pause_ctrl_phy: 0
# tx_pause_ctrl_phy: 15234
# All RoCE counters at once
rdma statistic show link mlx5_0/1Common Issues
DTS shows no metrics
- Cause: Missing
/dev/infinibandmount or no RDMA devices on node - Fix: Verify
ls /dev/infiniband/on host; ensure NIC drivers loaded (mlx5_core)
Counters stuck at zero
- Cause: No RDMA traffic flowing; or monitoring wrong port/device
- Fix: Run
ibstatto find active port; verifyDTS_DEVICES=allincludes correct NIC
Permission denied reading hw_counters
- Cause: Container not privileged; or SELinux blocking sysfs access
- Fix:
privileged: truein securityContext; or add specific capabilities (CAP_NET_ADMIN,CAP_SYS_RAWIO)
High PFC pause but no errors
- Cause: Normal back-pressure during large NCCL all-reduce β PFC is working correctly
- Fix: Only alert if pauses are sustained (>5min) or correlate with job slowdowns
Best Practices
- Deploy on all GPU worker nodes β network issues are often per-link, not cluster-wide
- 1-second collection interval β fast enough to catch transient congestion bursts
- Alert on retransmissions, not just errors β retrans indicates congestion before failures
- Correlate with DCGM metrics β GPU utilization drops often match network congestion spikes
- Baseline before production β know your normal PFC/ECN rates to set meaningful thresholds
- Monitor both directions β TX and RX pauses have different root causes
Key Takeaways
- DOCA Telemetry Service exposes NIC/DPU hardware counters as Prometheus metrics
- Key signals: RoCE retransmissions, PFC pause duration, ECN/CNP rates, port errors
- Deploy as DaemonSet with
hostNetwork: trueandprivileged: true - Alert on retransmissions (congestion), port errors (physical), link down (critical)
- Alternative: read
/sys/class/infiniband/counters directly or viaethtool -S - Correlate network telemetry with DCGM GPU metrics for full AI infrastructure observability

Recommended
Kubernetes Recipes β The Complete Book100+ production-ready patterns with detailed explanations, best practices, and copy-paste YAML. Everything in one place.
Get the Book βLearn by Doing
CopyPasteLearn β Hands-on Cloud & DevOps CoursesMaster Kubernetes, Ansible, Terraform, and MLOps with interactive, copy-paste-run lessons. Start free.
Browse Courses βπ Deepen Your Skills β Hands-on Courses
Courses by CopyPasteLearn.com β Learn IT by Doing